Multiple G codes were issued within the same group, causing previously designated G code to be ignored. The manual's first action is: “Reconsider the program.”
Too many addresses were specified in a single program block, causing previous address commands to be ignored. The manual's first action is: “Reconsider the program.”
More than one axis was commanded to move at the external deceleration speed simultaneously. The manual's first action is: “Invalidate external deceleration.”
Rotary axis workpiece position compensation exceeded the 3mm limit and is invalid. The manual's first action is: “Turn the rotary axis workpiece position compensation OFF.”
Tool offset was invalidated because a zero point return occurred during tool evasion return. The manual's first action is: “To reset the error, change the operation mode to a mode other than zero point return before t…
The F1-digit feedrate was set to zero, which is invalid for execution. The manual's first action is: “Set the F1-digit feedrate on the user parameter screen.”
An illegal operation was performed during NURBS interpolation mode. The manual's first action is: “Do not carry out MDI interrupt, etc., during NURBS interpolation.”
Chopping operation was attempted on a rotation axis, which is not allowed. The manual's first action is: “Chopping cannot be commanded to the rotation axis.”
An error occurred internally during the restart search process. The manual's first action is: “Execute from the restart top search after resetting.”
A top search was not completed before a restart search was attempted. The manual's first action is: “Execute a top search.”
The internal temperature of the NC or operation board has exceeded safe limits due to overheating. The manual's first action is: “Cooling measures are required. Turn OFF the NC power, or lower the temperature with an …
The tool has reached its maximum allowed usage or time limit and needs replacement. The manual's first action is: “Replace the tool.”
The machine attempted to start while initializing the absolute position detection system. The manual's first action is: “Start after the zero point initialization is completed.”
Starting was attempted during an absolute position detection alarm. The manual's first action is: “Start after canceling the absolute position detection alarm.”
Starting was attempted during an emergency stop condition. The manual's first action is: “Restart after canceling the emergency stop.”