An "LC" or "00" error code means the unit is beginning to lime up and must be flushed before further damage occurs. The manual's first action is: “Failure to flush the appliance will cause damage to the heat exchanger…
Scale Build-up in Heat Exchanger indicates lime buildup that requires flushing to prevent damage. The manual's first action is: “Refer to instructions in manual.”
Flame Sensing Device Fault occurs when the flame rod isn't touching the flame, has carbon build-up, or micro amp output is abnormal. The manual's first action is: “Check all wiring to flame rod for damage.”
SV0, SV1, SV2, and SV3 Solenoid Valve Circuit Fault means wiring to any of these solenoids is damaged or loose. The manual's first action is: “Measure resistance of each solenoid valve coil.”
Combustion Fan Failure indicates the fan does not turn freely or motor winding resistance is abnormal. The manual's first action is: “Check wiring harness to motor for damaged and/or loose connections.”
Modulating Solenoid Valve Signal Abnormal means there is damage or looseness in the valve's wiring harness. The manual's first action is: “Measure resistance of valve coil.”
Combustion Air Temperature Sensor Fault occurs due to restricted airflow, damaged sensor wiring, or a loose fan blade. The manual's first action is: “Check sensor wiring for damage.”
Heat Exchanger Outgoing Temperature Sensor Fault indicates sensor wiring damage or scale build-up on the sensor. The manual's first action is: “Measure resistance of sensor.”
Outgoing Water Temperature Sensor Fault means the sensor wiring may be damaged or scale build-up has occurred on the sensor. The manual's first action is: “Measure resistance of sensor.”
Over Temperature Warning occurs when air flow is restricted or there are foreign materials in the combustion chamber or exhaust piping. The manual's first action is: “Check for low water flow in a circulating system c…
Thermal Fuse indicates a problem with gas type mismatch or restricted airflow, possibly due to foreign materials in combustion chamber or exhaust piping. The manual's first action is: “Check for restrictions in air fl…
All 11 error codes of the Rheem 305, 505, 705 tankless water heater with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Selected by PAR 1624 START ENABLE 4 alarm occurs when the RUN Enable condition is not satisfied. The manual's first action is: “Check 24 Volts on RBCU unit”
START ENABLE 3 alarm happens when a start command is given but the RUN Enable condition is not satisfied. The manual's first action is: “Run Enable condition is not satisfied. Bad 24v supply Bad digital input 24 V com…
START ENABLE 2 alarm occurs when a start command is given but the RUN Enable condition is not satisfied. The manual's first action is: “Run Enable condition is not satisfied. Bad 24v supply Bad digital input 24 V comm…