Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The M1 contactor is stuck and unable to move during power-up or after being commanded to open, indicating a potential mechanical or electronic fault. The manual's first action is: “Disconnect incoming power from unit.…
The M2 contactor is stuck and unable to move during power-up or after being commanded to open, indicating a potential mechanical or electronic fault. The manual's first action is: “Disconnect incoming power from unit.…
The RBCU has detected abnormal current feedback when neither contactor should be energized. The manual's first action is: “Change RBCU”
The drive is warning that parameter 1606 LOCAL LOCK is active, preventing the OFF key from stopping the motor in AUTO mode. The manual lists no action for this code.
This error code is reserved for future use and has no defined meaning at this time. The manual lists no action for this code.
The drive is warning that PFA interlocks are active, preventing it from starting any motor under current conditions. The manual's first action is: “Any motor (when Autochange is used), The speed regulated motor (when …
The drive is warning that the PFA autochange function has been activated and is currently in use. The manual's first action is: “To control PFA, use parameter Group 81: PFA CONTROL”
The drive is warning that it will automatically reset after a fault, which may restart the motor without user intervention. The manual's first action is: “To control automatic reset, use parameter Group 31: AUTOMATIC …
The drive has detected the motor is operating in the stall region and warns of an impending motor stall fault trip. The manual's first action is: “This alarm warns that a Motor Stall fault trip may be near.”
The drive has detected that the motor load is lower than expected, warning of a possible motor underload fault trip soon. The manual's first action is: “Check: Motor and drive ratings match (motor is NOT undersized fo…
The drive has detected the motor is hot, indicating potential motor underload fault trip risk based on estimated or sensor feedback temperature. The manual's first action is: “Check: Check for overloaded motor. Adjust…
The drive is warning that its heatsink is overheating and a device overtemperature fault may occur soon. The manual's first action is: “Check for and correct: Fan failure. Obstructions in the air flow. Dirt or dust co…
The drive has lost communication with the control panel, either because it’s in local mode or remote mode with specific parameter settings. The manual's first action is: “To correct check: Communication lines and conn…
The drive has detected that Analog Input 2 is missing or its value is below the minimum threshold set by the user. The manual's first action is: “Check: • Input source and connections • Parameter that sets the minimum…
The drive has detected that Analog Input 1 is missing or its value is below the minimum threshold set by the user. The manual's first action is: “Check: • Input source and connections • Parameter that sets the minimum…