Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Hardware fault--STO phase loss indicates a phase loss in safety terminal input wiring. The manual's first action is: “Ensure the safety terminal input wiring is proper.”
Hardware fault--Regenerative transistor fault happens when the external regenerative brake resistor is improperly or disconnected. The manual's first action is: “1. Check the connections B2 and B3 when the regenerativ…
Hardware fault--Fan fault occurs when the built-in fan stops running, requiring foreign material check and possible drive replacement. The manual's first action is: “Check whether there is a foreign material. If the a…
Hardware fault--AC power phase loss indicates one of the R, S, or T phases is missing in the power supply. The manual's first action is: “1. Ensure power wiring is proper. 2. Set P0.12 correctly.”
IPM fault occurs when the drive’s actual output current exceeds its specified limit, requiring cable check and possible replacement. The manual lists no action for this code.
CANopen fault—Incorrect parameter modification status happens when SDO attempts to modify parameters while the drive is not in Pre-OP or OP state. The manual's first action is: “Adjust the CANopen status machine to th…
CANopen fault—Bus load ratio too high occurs when a slave node receives too many frames for its baud rate support in asynchronous mode. The manual's first action is: “1. Modify the time interval for the master node to…
CANopen fault—Duplicate synchronization signal happens when multiple slave nodes generate synchronization signals in the network. The manual's first action is: “Modify configuration so that there is only one synchroni…
CANopen fault—Sending fault occurs when CAN communication is offline or the error receiving counter exceeds 128. The manual's first action is: “1. Check communication connection. 2. Restart the servo drive.”
CANopen fault—Receiving fault occurs when CAN communication is offline or error counter exceeds 128 on the INVT DA180 drive. The manual's first action is: “1. Check communication connection. 2. Restart the servo drive.”
CANopen fault—Synchronization signal too fast occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—PDO mapping not allowed occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—PDO modification not allowed in operational state occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—PDO mapping data not exist occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—Incorrect PDO mapping length occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.