CANopen fault—Modification not allowed for read-only occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—SDO data out of range occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—Incorrect SDO data length occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—SDO sub-index not exist occurs without specified cause for the INVT DA180 drive. The manual lists no action for this code.
CANopen fault—SDO index not exist occurs when an SDO read or write attempts an index that doesn't exist in the object dictionary on the INVT DA180 drive. The manual's first action is: “Check the index on the master no…
CANopen fault—CANopen offline occurs when the master node does not receive heartbeat packets from a slave node within a period of time on the INVT DA180 drive. The manual's first action is: “Check communication connec…
Application fault—Inertia identifying failed happens when the motor stops rotating with vibration longer than 3.5s during inertia identification on the INVT DA180 drive. The manual's first action is: “1. Improve the m…
Application fault—Homing offside occurs when a limit switch or software limit is enabled during homing on the INVT DA180 drive. The manual's first action is: “Modify the setting of P5.10 and then execute homing after …
Application fault—Encoder offset angle test failed occurs when there is great fluctuation in current feedback during encoder offset angle testing on the INVT DA180 drive. The manual's first action is: “Reduce the sett…
Application fault—Encoder offset angle test timeout happens due to an exception during encoder offset angle testing on the INVT DA180 drive. The manual's first action is: “Ensure the motor shaft can rotate freely and …
Drive overtemperature occurs when the ambient temperature of the INVT DA180 drive exceeds the specified limit. The manual's first action is: “1. Reduce the ambient temperature and improve the ventilation condition. 2.…
CANopen fault—Full position command buffer occurs because the PTP position command buffer is full on the INVT DA180 drive. The manual's first action is: “Increase the time interval for sending PTP control position com…
CANopen fault—Synchronization signal timeout happens when the time interval between synchronization frames exceeds twice the communication cycle on the INVT DA180 drive. The manual's first action is: “1. Check communi…
Position increment overflow occurs on the INVT DA180 drive. The manual lists no action for this code.
Hybrid control deviation too large occurs when electronic gear ratio conversion results in a single-variation position command exceeding 2^31-1. The manual's first action is: “FF01-1601h”