Position deviation fault occurs when server response is too slow causing residual pulses to exceed P4.33, or due to heavy load stalling. The manual's first action is: “8500-1600h”
Position overtravel—CW occurs when CW limit switch is touched, accumulated pulses exceed P0.36, or pulse frequency exceeds motor speed. The manual's first action is: “FF01-1501h”
Position overtravel—CCW occurs when CCW limit switch is touched or accumulated feedback pulse exceeds P0.35 setting. The manual's first action is: “FF01-1500h”
Speed deviation fault occurs when motor speed deviates from command in non-torque mode, possibly due to phase reversal. The manual's first action is: “8400-1400h”
Speed fault—Overspeed parameter set incorrectly occurs when P4.40 is less than 0 or P4.41 is greater than 0. The manual's first action is: “7180-1303h”
Speed fault—CW overspeed occurs when feedback speed exceeds P4.41 by more than 20ms in CW direction. The manual's first action is: “7180-1302h”
Speed fault—CCW overspeed occurs when feedback speed exceeds P4.40 by more than 20ms in CCW direction. The manual's first action is: “7180-1301h”
Speed fault—Overspeed occurs when motor speed exceeds P4.32 setting, possibly due to stalling or phase reversal. The manual's first action is: “7180-1300h”
Motor overtemperature occurs when the motor temperature exceeds its overheating protection threshold. The manual's first action is: “2310-1201h”
Motor overload occurs during long-term or short-term excessive motor loading. The manual's first action is: “2310-1200h”
Drive overload occurs when short-term load exceeds capacity. The manual's first action is: “FF01-1100h”
Main circuit undervoltage occurs when the DC voltage is too low, possibly due to low grid voltage or an open buffer relay. The manual's first action is: “3120-0D01h”
Main circuit overvoltage occurs when the DC voltage of the main circuit is higher than set, possibly from grid voltage or internal circuit damage. The manual's first action is: “3110-0D00h”
I/O fault—Pulse input frequency too high occurs when the detected pulse input frequency exceeds the specified limit, often due to an external signal being too fast. The manual's first action is: “FF01-0C02h”
I/O fault—Duplicate AI assignment occurs when analog input 3 is configured as a speed command in standard drive mode. The manual's first action is: “FF01-0C01h”