Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Module temperature is outside the permissible range on the Siemens G120C. The manual lists no action for this code.
Initialization error occurred, requiring a POWER ON (switch-off/switch-on) for all components on the Siemens G120C. The manual lists no action for this code.
Watchdog timer has expired due to wiring issues or timer discrepancies on the Siemens G120C. The manual's first action is: “- PROFiSafe: Remove contact problems/faults at the PROFIBUS master/PROFINET controller.”
The frequency of pulses at the measuring probe input is too high on the Siemens G120C. The manual's first action is: “- DI 1 (term. 6).”
An internal software error occurred while initializing terminal functions on the Siemens G120C. The manual's first action is: “- carry out a POWER ON (switch-off/switch-on) for all components.”
The connected power unit cannot be used with this Control Unit, as it is not supported on the Siemens G120C. The manual's first action is: “Fault value (r0949, interpret decimal):”
A data save to the memory card was unsuccessful due to insufficient space or file read error on the Siemens G120C. The manual's first action is: “- Memory card is defective.”
Too many data sets are configured, causing insufficient memory on the Siemens G120C. The manual's first action is: “reduce the number of data sets.”
Error in parameterization/configuration/commissioning procedure due to system limit exceeded on the Siemens G120C. The manual's first action is: “OFF2 IMMEDIATELY At least one system overload has been identified. Faul…
It is not possible to write into a write-protected file (PSxxxxxx.acx) on the Siemens G120C. The manual's first action is: “Check whether the "write protected" attribute has been set for the files in the non-volatile …
An error was detected evaluating parameter files PSxxxxxx ACX, PTxxxxxx ACX, CAXxxxxx ACX, or CCxxxxxx ACX saved in non-volatile memory on the Siemens G120C. The manual's first action is: “- check the parameters displ…
An error was detected when loading descriptive data saved in non-volatile memory on the Siemens G120C. The manual's first action is: “Replace the memory card or Control Unit.”
Error in parameterization/configuration/commissioning procedure for units changeover reference parameter value invalid on the Siemens G120C. The manual lists no action for this code.
For active PC master control, no sign-of-life was received within monitoring time, causing a return to BICO interconnection on the Siemens G120C. The manual's first action is: “Set the monitoring time higher at the PC…
An internal software timeout has occurred on the Siemens G120C. The manual's first action is: “Fault value (r0949, interpret decimal): Only for internal Siemens troubleshooting. Remedy: - carry out a POWER ON (switch-…