Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The F parameterization is inconsistent on the Siemens G120C, requiring correction of parameter settings. The manual lists no action for this code.
A CRC error occurred in the F parameters on the Siemens G120C, indicating a mismatch between transferred and calculated values. The manual lists no action for this code.
The F parameter version is incorrect on the Siemens G120C; it must be set to 0 for V1 mode or 1 for V2 mode at the PROFiSafe slave. The manual lists no action for this code.
The F-CRC length setting is incorrect on the Siemens G120C, with CRC2 requiring 2-byte and V2 requiring 3-byte CRC settings. The manual lists no action for this code.
The SIL level is incorrect on the Siemens G120C; it must be set to SIL2 at the PROFiSafe slave. The manual lists no action for this code.
The watchdog time setting is invalid on the Siemens G120C, and must not be set to 0 at the PROFiSafe slave. The manual lists no action for this code.
The source address is invalid on the Siemens G120C, as it cannot be set to 0 or FFFF at the PROFiSafe slave. The manual lists no action for this code.
The destination address is invalid on the Siemens G120C, requiring verification of settings on processor 1 (p9610) and processor 2 (p9810). The manual lists no action for this code.
The destination address and PROFIsafe address differ on the Siemens G120C, indicating a mismatch in settings at the PROFiSafe slave. The manual lists no action for this code.
An internal software error occurred on the Siemens G120C, reserved for internal Siemens troubleshooting. The manual lists no action for this code.
The STO terminal status differs between the two monitoring channels on the Siemens G120C. The manual lists no action for this code.
The delay timer SS1 status differs between the two monitoring channels on the Siemens G120C, as indicated by settings in p9650/p9850. The manual lists no action for this code.
The feedback signals for safe pulse suppression differ between the two monitoring channels on the Siemens G120C. The manual lists no action for this code.
The STO selection status differs between the two monitoring channels on the Siemens G120C. The manual lists no action for this code.
Module temperature is not plausible, requiring operation within permissible temperature range on the Siemens G120C. The manual lists no action for this code.