Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Brake fault occurred on the INVT DA180. The manual lists no action for this code.
Incorrect power module settings on the INVT DA180. The manual lists no action for this code.
Drive model not exist for the INVT DA180 setting. The manual lists no action for this code.
Phase-W IGBT fault on the INVT DA180. The manual lists no action for this code.
Phase-V IGBT fault occurs with no specified cause or action, indicating an internal component failure in the V-phase IGBT. The manual lists no action for this code.
Phase-U IGBT fault occurs with no specified cause or action, indicating an internal component failure in the U-phase IGBT. The manual lists no action for this code.
Fault code R3.00 is listed without a description. The manual lists no action for this code.
Fault code R0.99 is listed without a description. The manual lists no action for this code.
Application fault– Out-of-range in magnetic pole check happens when the motor motion exceeds specified limits during magnetic pole check, requiring P6.60 and P6.61 adjustments. The manual's first action is: “Increase …
Application fault– Overtail/overspeed in confirmation of magnetic pole check occurs when motor motion range is too large or speed is too fast during magnetic pole check, requiring P6.70 adjustment. The manual's first …
Application fault– Magnetic pole check failed happens due to incorrect power cable phase sequence or conflicting encoder direction during magnetic pole verification. The manual's first action is: “1. Ensure power cabl…
Overspeed fault—Motor runaway occurs when the servo motor loses control, requiring encoder and phase sequence check. The manual's first action is: “1. Ensure the encoder is connected properly. 2. Ensure the phase sequ…
Drive overload 2 indicates short-term load exceeds the drive’s capacity, requiring load reduction and motor/encoder verification. The manual's first action is: “1. Reduce the load. 2. Ensure there is no phase dislocat…
Hardware fault--STO DPIN2 fault occurs when Safety Terminal Input 2 is abnormal, requiring proper wiring check. The manual's first action is: “Ensure the safety terminal input wiring is proper.”
Hardware fault--STO DPIN1 fault occurs when Safety Terminal Input 1 is abnormal, requiring proper wiring check. The manual's first action is: “Ensure the safety terminal input wiring is proper.”