Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The motor temperature has exceeded its alarm threshold, triggering a response based on parameterized settings. The manual's first action is: “PTC or bimetallic NC contact: The response threshold of 1650 Ohm was exceed…
One phase of the brake resistor has failed, indicated by a specific fault code for each phase. The manual's first action is: “Fault value (r0949, interpret decimal): 11: Phase U 12: Phase V 13: Phase W”
The braking resistor phases are not symmetrical or experiencing oscillations from fluctuating loads. The manual lists no action for this code.
The measured DC voltage is outside the tolerance range after precharging, requiring drive shutdown to acknowledge the fault. The manual lists no action for this code.
Voltage measurements are not providing plausible values, indicating a possible wiring or parameterization issue. The manual's first action is: “- Deactivate voltage measurement (p0247.0 = 0). - Deactivate flying resta…
The rectifier temperature has exceeded its alarm threshold, possibly due to ambient heat or fan failure. The manual's first action is: “Check the following: - is the ambient temperature within the defined limit values…
The cyclic connection to the PROFIBUS master has been interrupted. The manual's first action is: “Establish the PROFIBUS connection and activate the PROFIBUS master in the cyclic mode.”
The fieldbus interface failed to receive setpoints, likely due to an interrupted bus connection or communication partner turning off. The manual's first action is: “See also: p2040 (Fieldbus interface monitoring time)…
The system has detected a defect before or during the last boot, possibly due to a reset. The manual's first action is: “- carry out a POWER ON (switch-off/switch-on).”
The SI parameters could not be copied on the Siemens G120C because p9700 was set to 208 or entered offline. The manual's first action is: “- set p9700 to 0.”
An internal communication error occurred within a module on the Siemens G120C, requiring a power cycle to resolve. The manual's first action is: “- carry out a POWER ON (switch-off/switch-on).”
Synchronization of safety time slices between processor 1 and 2 failed on the Siemens G120C, indicating an internal hardware/software error. The manual's first action is: “OFF2”
The Control Unit must be replaced on the Siemens G120C due to a failure. The manual lists no action for this code.
A time monitoring timeout was detected during reception of the PROFIsafe telegram on the Siemens G120C. The manual lists no action for this code.
A communication error occurred while receiving the PROFIsafe telegram on the Siemens G120C, possibly due to outdated or inconsistent data. The manual lists no action for this code.