Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The power unit has detected a checksum (CRC) error, which may be resolved by performing a full POWER ON cycle for all components. The manual's first action is: “- carry out a POWER ON (switch-off/switch-on) for all co…
A booting error has occurred during power-up, indicating a critical failure in initialization that requires resetting with OFF2. The manual's first action is: “OFF2”
An internal communication error has occurred within the drive’s hardware or software system, requiring a reset via OFF2. The manual's first action is: “OFF2”
A write request to one or more Safety Integrated parameters on processor 2 was rejected during parameterization or configuration, without triggering a safety stop. The manual's first action is: “OFF2”
An error occurred while accessing the Safety Integrated parameters for processor 2 in non-volatile memory, requiring acknowledgment before proceeding. The manual lists no action for this code.
Processor 1 and processor 2 were unable to align their Safety Integrated monitoring functions due to communication errors or incompatible configurations. The manual lists no action for this code.
The safety time slices on processor 1 and processor 2 failed to synchronize, preventing safe operation and resulting in a non-acknowledgeable STOP A. The manual lists no action for this code.
Processor 2 of the drive’s Safety Integrated function requires an acceptance test to verify its operational integrity before resuming operation. The manual lists no action for this code.
An internal software error has occurred within the Safety Integrated system on processor 2. The manual lists no action for this code.
Processor 2 of the drive’s Safety Integrated function has detected an error in the safety data sign-of-life, indicating communication or software timing issues. The manual lists no action for this code.
The Safety Integrated function on processor 2 has detected a data cross-check failure between monitoring channels, triggering a STOP F and causing fault F30600. The manual lists no action for this code.
Processor 2 of the drive’s Safety Integrated function has initiated a STOP A because it detected an error in its safety signal path or failed to respond to fault F30611. The manual's first action is: “0: Stop request …
The power unit has detected overvoltage on the DC link during a pulse inhibit, possibly due to excessive supply voltage or an incorrectly dimensioned line reactor. The manual's first action is: “- check the device sup…
The inverter heat sink temperature is below the permissible minimum, indicating the ambient temperature is too low or the sensor evaluation is defective. The manual's first action is: “- the power unit is being operat…
The internal fan of the power unit has failed and is no longer functioning properly. The manual's first action is: “Check the internal fan and replace if necessary.”