Agilent manuals, page 66
Agilent Linearized MCT detectors for superior photometric accuracy sensitivity Manual
Agilent’s linearized mercury cadmium telluride (MCT) detector technology delivers substantial advantages for quantitative measurements. It extends the linear range of the detector versus energy flux relationship by about a factor of ten above the range that can be obtained with a standard MCT detector, while still maintaining high photometric accuracy. As a result, a wider concentration range can be achieved when performing quantitative measurements, so you can avoid time-consuming dilutions, providing greater productivity and lower running costs for your laboratory.
Agilent Determination of low-metal release from the Agilent 1260 Infinity Bio-inert Quaternary LC system using ICP-MS Manual
The Proof of Performance Determination of low-metal release from the Agilent 1260 Infi nity Bio-inert Quaternary LC system using ICP-MS provides the details of the analysis.
Agilent Performance characteristics of the 1260 Infinity Bio-inert Quaternary LC System Manual
The Agilent 1260 Infinity Bio-inert Quaternary LC system has the same performance specifications as the standard Agilent 1260 Infinity Quaternary LC system based on the proven technology of the Agilent 1200 Infinity Series. This Technical Overview proves that method transfer from an Agilent 1260 Infinity Series Quaternary LC system to an Agilent 1260 Infinity Bio-inert Quaternary LC system will typically result in chromatograms with no significant differences including compatibility with standard methods with a maximum pressure of 600 bar. In addition, it is especially well suited for bio-analytical applications, such as, protein analysis using ion exchange chromatography (IEX) or size exclusion/gel filtration (SEC).
Agilent MP Expert Software Technical Overview Manual
Agilent 4100 MP-AES provides a low-cost multi-element analysis technique based on a microwave-generated plasma that runs using only nitrogen as opposed to fl ammable gases such as acetylene. This improves laboratory safety, while reducing the diffi culties associated with sourcing and replacing fl ame AA gases — especially in remote areas. With excellent long-term stability, improved linear dynamic range, superior detection limits, and faster measurement compared with fl ame AA, the Agilent 4100 MP-AES is the perfect analysis tool for achieving your productivity and profi tability goals, with the lowest cost of analysis. Part of what makes the Agilent 4100 MP-AES such an easy system to work with is the Agilent MP Expert software that controls the instrument. With a familiar worksheet interface, automated method development, and software applets that automatically load pre-set method templates, the Agilent MP Expert software dramatically simplifi es analysis.
Agilent Time- peak-based fraction collection with the Agilent 1220 Infinity LC System Manual
This document is a technical overview of the Agilent 1220 Infi nity LC System. The system can be used for analytical-scale purifi cation of compounds. It is easy to operate and has a flow rate of up to 10 mL/min. The Agilent 1260 Infi nity Analytical-scale Fraction Collector can be used to collect fractions based on time and peak baseline.
Agilent ICP-MS MassHunter WorkStation Software (G7201A) for the Agilent 7700 Series ICP-MS Manual
Agilent's MassHunter is a powerful, easy-to-learn software that provides a common platform across Agilent's LC/MS, GC/MS, and ICP-MS systems. It simplifies the transfer of skills across the laboratory with its common user interface and standard terminology. The latest revision of ICP-MS MassHunter software (G7201A, A.01.02) offers configuration, setup, and control of the Agilent 7700 Series ICP-MS hardware and accessories, as well as method setup, acquisition, data processing, and reporting through a modern, integrated, and intuitive user interface.
Agilent VGA 77 High productivity vapor generation Manual
Agilent VGA 77 Vapor Generation Accessory is a precision instrument for rapid determination of mercury and other hydride forming elements.
Agilent Enhancing the maximum injection volume of the Agilent 1290 Infinity Autosampler Manual
This Technical Overview demonstrates the performance of the Agilent 1290 Infi nity Autosampler with increased injection volume capability up to 120 µL.
Agilent Seamless transfer of elution gradients from Agilent 1100/1200 Series LCs to an Agilent 1290 Infinity LC using ISET Manual
This document introduces Agilent Intelligent System Emulation Technology (ISET) technology, which can be used to achieve seamless method transfer from Agilent 1100/1200 Series LCs to Agilent 1290 Infi nity LC. Using ISET, the same chromatographic results can be achieved without any modifications to the instrument or changes to the original method. The document demonstrates through experiments that gradients run on an Agilent 1100 Series LC System, including typical linear gradients as well as gradients with dif- ferent slopes, steps, and isocratic parts, correlate almost 100% to gradient profi les created on the Agilent 1290 Infi nity LC System with ISET.
Agilent Fully Using Agilent High Efficiency Columns with LC/MS Manual
This document introduces the use of Agilent high efficiency columns with LC/MS
Agilent Using the Agilent Instrument Control Framework to control the Agilent 1290 Infi nity LC through Waters Empower software Manual
The Agilent Instrument Control Framework (ICF) enables other providers of LC data acquisition and processing software to simplify the development of the control of Agilent LC instrumentation. In this Technical Overview we demonstrate how Agilent ICF facilitates enhanced control of the Agilent 1290 Infi nity LC through Waters Empower chromatography data software versions 2 and 3. The combination of Agilent ICF and Waters Empower software provides easy access to advanced features of the 1290 Infi nity LC such as priming and purging the pump, external needle wash, and acquisition of all eight MWD and DAD signals.
Agilent Using the Agilent Instrument Control Framework to control the Agilent 1220 Infinity LC system through Waters Empower software Manual
This document describes how to control the Agilent 1220 Infinity LC system through Waters Empower chromatography data software using the Agilent Instrument Control Framework (ICF). The combination of Agilent ICF and Waters Empower software provides easy access to advanced features of the 1220 Infinity LC system, such as overlapped injections.
Agilent Solid-state NMR Analysis of Biomolecules: New BioSolids Experiments for VnmrJ 3.2 BioPack Manual
This document describes the Agilent BioSolids Pack, which is a repository for SSNMR sequences designed to investigate protein samples.
Agilent Method development on the Agilent 1290 Infinity LC using Intelligent System Emulation Technology (ISET) with subsequent transfer to an Agilent 1100 Series LC Manual
This Technical Overview shows the development of a chromatographic method for the analysis of paracetamol and its impurities using 1290 Infi nity LC System with ISET. Having developed the method it was transferred to an Agilent 1100 Series Quaternary LC System.
Agilent 1260 Infinity Hybrid SFC/UHPLC System Manual
This document introduces a hybrid technology that integrates supercritical fluid chromatography and ultra-high performance liquid chromatography, which significantly improves the separation performance of complex mixtures.