Agilent manuals, page 70
Agilent ChemStation for GC LC LC/MSD CE A/D Systems - Rev. 09.0x Manual
Agilent ChemStations is an instrument control, data acquisition and data evaluation system for gas chromatographs, liquid chromatographs, liquid chromatography tandem mass spectrometry, capillary electrophoresis systems and analog-to-digital interfaces
Agilent G2565BA Microarray Scanner Bar Code Glass Specifications handbook(1)
This document describes the bar code and glass specifications of Agilent G2565BA microarray scanner
Agilent G2565BA Microarray Scanner Bar Code Glass Specifications handbook
This data sheet lists the specifications of the glass on which the active microarray is printed, and the region in which the microarray may be scanned.
Agilent G2565BA Microarray Scanner Bar Code Glass Specifications Manual
This data sheet provides the bar code and glass specifications for the Agilent G2565BA microarray scanner.
Agilent MSD Security ChemStation for GC/MS Systems Rev A.02.00 Manual
Agilent MSD Security ChemStation is a data management software that can be used to control data acquisition, perform library searches and quantitative analysis, and generate selected reports via methods or sequences. The software addresses all aspects of data security, integrity, and traceability mandated by FDA’s 21 CFR Part 11. The solution represents a significant productivity advance for pharmaceutical laboratories. Access to the application is protected by a mandatory logon with a user identification code and password. Paper trails are replaced by audit-proof and reliable electronic records. The software manages versions electronically and provides a user-independant audit trail along with electronic signing capabilities. Electronic records generated by the application are always linked to all related raw, meta, and result data. The MSD Security ChemStation software is designed to run on personal computers with Microsoft® Windows® operating environments. The MSD Security ChemStation software is supplied on CD-ROM and contains extensive online help with both task and reference information about system operation. The example methods and data files supplied with the software can be used to practice and learn the MSD Security ChemStation software. The MSD Security ChemStation software can be configured to support a single online instrument, with a maximum of one MSD and one GC detector. The following Agilent instruments are supported: • The new 5975 series MSDs 5973A, 5973N, and 5973 inert MSDs • 6850 GC p
Agilent Cerity Networked Data System for Chemical QA/QC (A.04.03) Manual
Agilent Cerity Networked Data System for Chemical QA/QC is designed for routine QA/QC laboratory environments.
Agilent 35900E Dual-Channel Interface with Modular Input/Output Manual
This document introduces a dual-channel interface device called 35900E. The device features a Motorola 68331 processor and 1MB RAM memory. It has an input signal voltage range of -18mV to +1.0V and offers a high analog dynamic range and resolution. The device also has good common-mode rejection and thermal drift performance, and maintains RFI immunity in a wide frequency range.
Agilent ChemStation Manual Rev. B.02.01
User Manual 40 pages · 199 KB · ENThis manual details the Agilent ChemStation software Rev. B.02.01, its features, system requirements, and supported instruments.
Agilent MSD Productivity ChemStation User Manual Rev. D.03.00
User Manual 22 pages · 249 KB · ENThe Agilent MSD Productivity ChemStation User Manual (Rev. D.03.00) explains software installation, instrument control, data acquisition, and analysis for…
Agilent 3100 OFFGEL Fractionator Specifications Manual
This document describes the specifications and features of the Agilent 3100 OFFGEL Fractionator. The instrument is lightweight and compact, with wide ranging capability for voltage and frequency. It has high resolution and multiple modes to choose from. The instrument has programmable timetable and individual current control for each sample. It also has high loading capacity and multiple types of consumables.
Agilent Microarray Printable Areas - SureHyb Hybridization Chambers Manual
This document introduces the features and usage methods of Agilent Microarray Hybridization Chambers (SureHyb enabled).
Agilent ChemStation for GC LC LC/MSD CE A/D Systems - Revision B.03.01 Manual
Agilent Chemstation Revision B.03.01 is the next step in active development of the Agilent ChemStation. Its new User Interface addresses customer's growing needs for faster acquisition and review of data. A modern tree view along with a new navigation table allows easy finding, sorting and review of multiple sample data. It adopts new Microsoft technologies while maintaining well known ChemStation concepts to avoiding need of re-training.
Agilent Specifications at a Glance Manual
This file is the specification sheet of CombiPAL liquid autoinjector
Agilent Markes CIA8 Specification Sheet Manual
This file is the CIA 8 specification sheet released by Markes International, which introduces the functions and features of CIA 8, including the ability to be used for tagged or untagged tubes, provides a universal TD platform, compatible with all TD applications, uses an electrically cooled focusing trap and a patented inert heated valve to ensure the recovery of the broadest range of analytes, including C2 to n-C40 hydrocarbons and reactive species such as mercaptans.
Agilent Markes Air Server Series 2 Specification Sheet Manual
Air Server 3 is a portable gas sampler for UNITY 2. It can collect vapor phase organics from three gas channels (typically sample, standard and zero gas) and perform cryogen-free concentration with UNITY 2. The sampling process is fully automated via software.
