Agilent manuals, page 63
Agilent Technologies ZORBAX 300SB-C18 1.8 m Rapid Resolution High Definition Columns for Proteins service manual
Agilent ZORBAX RRHD 300SB-C18 1.8 µm is a new reverse phase media for UHPLC analysis of proteins and peptides. By utilizing StableBond technology, it provides a stable 300Å pore-size media under acidic conditions for robust and reproducible protein separations.
Agilent Technologies Analysis of Hydrocarbons by GPC using OligoPore Columns service manual
Introduces the role of Agilent OligoPore Columns in high temperature GPC separation and analyzes the characteristics of the product
Agilent Technologies Repeatability in High Temperature Polypropylene Analysis Using Agilent PLgel MIXED-B service manual
This document presents a repeatability study of polypropylene analysis using Agilent PLgel MIXED-B columns and the Agilent PL-GPC 220 integrated, high temperature instrument. The system's ability is demonstrated through the analysis of six polypropylene injections. A commercial sample of polypropylene was prepared at 1.5 mg/mL using the PL-SP 260 sample preparation system with a dissolution temperature of 160 °C and a dissolution time of two hours. Six aliquots of the master batch solution were dispensed into the PL-GPC 220 autosampler vials and placed in the carousel where the hot zone temperature was 160 °C and the warm zone was 80 °C. Figure 1 shows an overlay of the raw data chromatograms obtained for the six consecutive injections of the sample. The data were analyzed against a polystyrene standards calibration using the provided Mark-Houwink parameters to obtain the polypropylene equivalent molecular weight averages shown in Table 1.
Agilent Technologies Performance characteristics of the High Sensitivity DNA assay for the Agilent 2100 Bioanalyzer service manual
This document introduces the Agilent High Sensitivity DNA kit, which can be used for sizing, quantification and quality control of DNA fragments. The kit's sensitivity is up to pg/µL, and it can detect DNA fragments in the range of 50-7000bp.
Agilent Technologies Performance optimization using the Agilent 1260 Infinity Analytical SFC System service manual
This Application Note describes how to optimize a typical SFC separation by changing: • System backpressure • Modifi er concentration • Column temperature
Agilent Technologies Preparative Gel Permeation Chromatography - Recycling service manual
This document provides an overview of preparative gel permeation chromatography, which improves the resolution of sample components by recycling the sample back through the column multiple times before fraction collection, thus conveniently minimizing cross-fraction contamination. The high column volume of the Agilent PLgel 10 µm 100 Å, 25 × 300 mm prep column facilitates recycle capability. Improved resolution after three cycles is observed.
Agilent Technologies Preparative Gel Permeation Chromatography - Loading service manual
Describes the importance of loading in preparative gel permeation chromatography (GPC) and how loading can be significantly increased for very low molecular weight materials such as epoxy resins.
Agilent Technologies Selecting Agilent Columns for Gel Permeation Chromatography service manual
This document introduces the application of Agilent MIXED gel technology in gel permeation chromatography and size exclusion chromatography columns. This technology allows different pore size gels to be blended together to create a column with a linear calibration suitable for a specific molecular weight range. Selectivity in GPC/SEC separations can be controlled by adjusting the column length and the pore size distribution of the packing material. Compared to individual pore size gels, MIXED gel packing provides a larger molecular weight range and better separation performance.
Agilent SurePrint Technology. Content centered microarray design enabeling speed flexibility Manual
Agilent SurePrint Technology is content centered microarray design enabling speed and flexibility
Agilent The DirectDigital Receiver (DDR): Universal Receiver for all NMR Applications Manual
Agilent DirectDigital Receiver Manual
This document introduces the advantages of Agilent NMR System's DirectDigital Receiver, including high accuracy and better signal-to-noise
Agilent 1260 Infinity SFC/MS Solution Manual
This document describes the Agilent 1260 Infinity SFC/MS solution, which provides superior sensitivity by seamlessly interfacing to the Agilent 6100 Series LC/MS system
Agilent The Salt Tolerant Cold Probe Manual
Agilent Salt Tolerant Cold Probe provides the highest sensitivity for lossy samples such as proteins in aqueous solutions containing high concentrations of buffer or salt
Agilent 13C CPMAS with the NMR System Manual
Agilent NMR System 13C CPMAS with the Agilent NMR System,introduces the advantages of using Agilent NMR System for 13C CPMAS. The experiment used Agilent 400 MHz NMR system and Agilent 3.2 mm T3 HFXY probe, and obtained the HMB test spectrum.
Agilent The OneNMR Probe for Routine Chemical Applications Manual
Agilent OneNMR probe is a new NMR probe that can simultaneously detect 13C and 1H, and its performance is excellent.
