Key facts
- Brand
- Panasonic
- Model
- MINAS A5
- Category
- Servo motor
- Documents
- 8
- Languages
- EN · ES · ZH
- Last added
- 2026-09-29
Start here

Panasonic MINAS A5/A6 Servo Drive Quick Start Guide – PANATERM Fit‑gain Tuning
The guide introduces the PANATERM fit‑gain tuning procedure for MINAS servo drives, describing the required software, safety notes, and the purpose of auto‑tuning to improve positioning performance. It also lists related documents and available free software such as PANATERM QS5002_V1.0.
A functional overview explains the two auto‑tuning options (fit‑gain and real‑time auto‑gain). Detailed wiring instructions cover power, motor, encoder, and PC connections, followed by step‑by‑step instructions for performing fit‑gain tuning using the PANATERM configuration software. The document ends with contact information for support and a record of changes.
Panasonic MINAS A5 specifications
| Single-phase supply voltage | 230 V |
|---|---|
| Motor phase labels | U, V, W |
| PC connection cable | USB A to mini-B |
Source: Panasonic MINAS A5/A6 Servo Drives and Motors Quick Start Guide
All Panasonic MINAS A5 documents by type
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Can the servomotor be moved manually without an external control unit?
Yes, PANATERM can move the servomotor manually without connecting an external control unit such as a PLC, CNC, or encoder.
From: Panasonic MINAS A5/A6 Servo Drives and Motors Quick Start Guide
When should trial run movements be performed?
Trial run movements should only be performed when the motor shaft is disconnected from the machine.
From: Panasonic MINAS A5/A6 Servo Drives and Motors Quick Start Guide
How is the motor torque controlled?
The torque is controlled by analog signals, for example 0 to 10 V, at the analog inputs of the servo driver. A speed limit signal is also required to limit the motor speed.
From: Panasonic MINAS A5/A6 Servo Drives Quick Start Guide Torque Control
How many torque control modes are there?
There are three different torque control modes. This Quick Start Guide describes torque command 0, which uses analog input 1 and a motor speed limit.
From: Panasonic MINAS A5/A6 Servo Drives Quick Start Guide Torque Control
What safety precautions must be taken regarding the installation area?
The installation area should be away from heat-generating objects such as a heater and a large wire wound resistor.
From: Panasonic MINAS A5-series AC Servo Motor & Driver Operating Instructions
What type of material must the motor, driver, and peripheral equipment be mounted on?
They must be mounted on incombustible material such as metal to prevent fire.
From: Panasonic MINAS A5-series AC Servo Motor & Driver Operating Instructions