Key facts
- Brand
- Fluke
- Model
- 77IV
- Category
- Other Electronics
- Industry
- Electronics
- Documents
- 2
- Languages
- EN
- Last added
- 2026-11-24
Start here

Fluke 77IV Digital Multimeter Technical Data
This technical data sheet describes the Fluke 77IV digital multimeter, a versatile meter for field service or bench repair with a wide 1000 V measurement range, average responding AC measurements, 0.3 % accuracy, 20 A for 30 seconds, frequency and capacitance, and resistance and continuity.
It lists general specifications such as display counts, operating and storage conditions, battery life, size, weight, safety compliance, certifications, measurement functions with ranges, resolutions and accuracies, and ordering information.
Fluke 77IV specifications
| Maximum voltage between any terminal and earth ground | 1000 V |
|---|---|
| Surge protection | 8 kV peak per IEC 61010 |
| Fuse for mA input | 440 mA, 1000 V FAST Fuse |
| Fuse for A input | 11 A, 1000 V FAST Fuse |
| Digital display | 6,000 counts, updates 4/sec |
| Bar graph | 33 segments, updates 32/sec |
| Frequency display | 10,000 counts |
| Capacitance display | 1,000 counts |
| Operating altitude | 2,000 meters |
| Storage altitude | 12,000 meters |
| Operating temperature | -10 °C to +50 °C |
| Storage temperature | -40 °C to +60 °C |
| Battery life | 400 hours typical (Alkaline) |
| Size (H x W x L) | 4.3 cm x 9 cm x 18.5 cm |
| Weight | 420 g |
| AC volts accuracy | 2.0 % + 2 (45 Hz to 1 kHz) |
| AC amps accuracy | 2.5 % + 2 (45 Hz to 1 kHz) |
All Fluke 77IV documents by type
Questions answered in these manuals
What is included with the Fluke-77-4 digital multimeter?
TL75 test leads, a user’s manual, and a 9 V battery (installed).
What is the maximum voltage between any terminal and earth ground?
1000 V.
What is the battery life of the Fluke 77IV?
The battery life is typically 2000 hours.
How many counts does the digital display have?
The digital display provides 3200 counts.