Fluke 106 Manuals

ManualLib has 4 documents for the Fluke 106 (multimeter): 1 product leaflet, 3 user manuals. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1User Manual 3

Key facts

Brand
Fluke
Model
106
Category
multimeter
Industry
Electronics
Documents
4
Languages
ZH · EN
Last added
2026-11-16

Start here

Fluke 106/107 Digital Multimeter User Manual

Fluke 106/107 Digital Multimeter User Manual

User Manual 34 pages · 3.4 MB · ZH

This is the Simplified Chinese user manual for the Fluke 106/107 digital multimeter. It begins with warranty and contact information, followed by detailed safety warnings, an explanation of the symbols used on the product, and an overview of the instrument's terminals and display.

The manual then describes operation: auto power off, backlight auto-off, data hold, measuring AC and DC voltage and current, measuring resistance, continuity testing and the diode test available on the 107 model. The final pages list accuracy specifications, ranges, resolution, input impedance and overload protection. This manual is written in Chinese.

Read online

Fluke 106 specifications

Measurement functionsVoltage, resistance, current, capacitance
Maximum AC/DC current input10 A
Accuracy validity conditionsWithin one year after calibration at 18 °C to 28 °C and 0 % to 75 % relative humidity
Display6000 counts, updated three times per second
BatteryTwo AAA batteries (NEDA 24A, IEC LR03)
Battery lifeAt least 200 hours
Dimensions142 mm x 69 mm x 28 mm
Operating temperature0 °C to 40 °C
Storage temperature-30 °C to 60 °C
Ingress protectionIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, pollution degree 2
Fuse protection11 A, 1000 V fast blow

Source: Fluke 106 Palm-sized Digital Multimeter Technical Data

All Fluke 106 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What measurement functions does the Fluke 106 provide?

It measures voltage, resistance, current and capacitance.

From: Fluke 106 Palm-sized Digital Multimeter Technical Data

What is the maximum AC/DC current input?

The input terminals can measure AC and DC current up to 10 A.

From: Fluke 106 Palm-sized Digital Multimeter Technical Data

What temperature range applies to the accuracy specifications?

Accuracy applies for one year after calibration at an operating temperature of 18 °C to 28 °C and relative humidity of 0 % to 75 %.

From: Fluke 106/107 Digital Multimeter User Manual

What is the maximum current the meter can measure?

The current input terminal is used for AC and DC current measurements up to 10 A.

From: Fluke 106/107 Digital Multimeter User Manual

What is the maximum voltage I can measure with the AC Volts function?

The maximum rated input for AC Volts is 600 V.

From: Fluke 106/107 Digital Multimeters Users Manual

What is the duty cycle for high current measurements?

The 10A duty cycle allows less than 7 minutes of operation on, followed by 20 minutes off.

From: Fluke 106/107 Digital Multimeters User's Manual