Fluke VT02, VT04 Manuals

ManualLib has 2 documents for the Fluke VT02, VT04 (Temperature sensors): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Fluke
Model
VT02, VT04
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-11-18

Start here

Fluke VT02 VT04 Visual IR Thermometer Users Manual

Fluke VT02 VT04 Visual IR Thermometer Users Manual

User Manual 38 pages · 3 MB · EN

This is the users manual for the Fluke VT02 and VT04 Visual IR Thermometers, instruments that combine surface temperature measurement with real-time thermal and visual images. It explains the controls, button operation, image blending and visual image alignment, and how to capture and save images to a Micro SD card.

The manual also covers menu functions, reviewing memory, emissivity and reflected background temperature compensation, spot temperature markers, color palettes, temperature units, and date and time. VT04-only features such as the Hi/Lo temperature alarm, time-lapse image capture and Auto-Monitor are described, followed by maintenance, battery care and full specifications for both models.

Read online

Fluke VT02, VT04 specifications

Temperature Measurement Range-10 °C to +250 °C
Temperature Measurement Accuracy±2 °C or ±2 % as tested (at 25 °C), whichever is the greater
Detector TypeUncooled pyroelectric ceramic
Thermal Sensitivity (NETD)≤250 mK
Infrared Spectral Band6.5 µm to 14 µm
Image Capture Frequency8 Hz
Field of View (VT02)20° X 20°
Field of View (VT04)28° X 28°
Storage MediumMicro SD memory card, stores up to 10,000 images/GB
Battery Type (VT04)Li-Ion Rechargeable, 3.6 V, 2250 mAh, 8.1 Wh
Battery Type (VT02)4 AA, LR6 1.5 V
Battery Life8 hrs
Operating Temperature-5 °C to +45 °C
Storage Temperature-20 °C to +60 °C
Size (H x W x L)21 cm x 7.5 cm x 5.5 cm (8.3 in x 3 in x 2.2 in)
Weight (Battery Included)<300 gm (10.5 oz)
Warranty2 years

Source: Fluke VT02 VT04 Visual IR Thermometer Users Manual

All Fluke VT02, VT04 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the temperature measurement range of the VT02 and VT04?

The measurement range is -10 °C to +250 °C.

From: Fluke VT02 VT04 Visual IR Thermometer Users Manual

How accurate is the temperature measurement?

Accuracy is ±2 °C or ±2 % as tested at 25 °C, whichever is the greater.

From: Fluke VT02 VT04 Visual IR Thermometer Users Manual

What is the battery life of the VT04?

The battery life is 8 hours.

From: Fluke VT02, VT04 Visual IR Thermometer User Manual

When does the device enter power save mode?

The device powers down after 10 minutes of inactivity.

From: Fluke VT02, VT04 Visual IR Thermometer User Manual