Key facts
- Brand
- Fluke
- Model
- 116
- Category
- Other Electronics
- Industry
- Electronics
- Documents
- 8
- Languages
- JA · ES · EN · ZH
- Last added
- 2026-11-20
Start here

Fluke 116 True-rms Multimeter User Manual
The Fluke 116 is a battery-powered true-rms multimeter with a 6000-count display and bar graph. It conforms to CAT III of the IEC 61010-1 2nd Edition safety standard.
This manual covers safety information, display symbols, terminals, error messages, rotary switch positions, and measurement ranges for the meter. This manual is written in Japanese.
Fluke 116 specifications
| Safety rating | CAT III, IEC 61010-1 2nd Edition |
|---|---|
| AC voltage range | 0.06 V to 600 V |
| Frequency range | 5 Hz to 50 kHz |
| DC voltage range | 0.001 V to 600 V |
| AC mV range | 6.0 mV to 600 mV |
| DC mV range | 0.1 V to 600 mV |
| Resistance range | 0.1 Ω to 40 MΩ |
| Continuity | On below 20 Ω, off above 250 Ω |
| Temperature range | -40 °C to 400 °C (-40 °F to 752 °F) |
| Diode test | OL above 2.0 V |
| Capacitance range | 1 nF to 9999 µF |
| DC current range | 0.1 µA to 600 µA |
| AC current range | 6.0 µA to 600 µA |
| Dangerous voltage threshold | 30 V or more |
All Fluke 116 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Fluke 116 True-rms Multimeter User Manual 24 p
- Fluke 116 True-rms Multimeter User Manual 22 p
- Fluke 116 True-rms Multimeter User Manual 24 p
- Fluke 116 True-rms Multimeter Users Manual 22 p
- Fluke 116 True-rms Multimeter Users Manual 24 p
- Fluke 116 HVAC Multimeter User Manual 2 p
- Fluke 116C True‑RMS Multimeter User Manual 24 p
Questions answered in these manuals
What does the Y symbol indicate?
It appears when a voltage of 30 V or more is measured.
What safety standard does the Fluke 116 conform to?
It conforms to CAT III of IEC 61010-1 2nd Edition.
How long is the warranty for the Fluke 116?
The warranty period is 3 years and begins on the date of dispatch.
When does Battery Saver mode activate?
If the meter is on but inactive and not connected to voltage for more than 20 minutes, the display blanks.
What safety category does the Fluke 116 meet?
The Fluke 116 meets CAT III IEC 61010-1 2nd Edition standards.
What is the display resolution?
The display has 6,000 digital counts and a 33-segment bar graph.