EMERSON NETWORK POWER 70-120 Watts NTQ123 Series(1)

EMERSON NETWORK POWER 70-120 Watts NTQ123 Series(1)

Datasheet 2 pages · 90 KB · EN

The NTQ123 Series from Emerson Network Power is a compact power supply offering 70 W convection‑cooled and up to 120 W forced‑air cooling. It supports a wide input voltage range (85‑264 VAC) and includes active power‑factor correction with a typical PF of 0.99.

Key features include overload and short‑circuit protection, remote‑sense on both outputs, adjustable output voltage, and built‑in Class B EMI filtering. The unit meets multiple safety and EMC standards (UL1950, CE, EN61000‑3‑2, etc.) and operates from 0 °C to 50 °C ambient temperature with a hold‑up time of 20 ms at full load.

Read online

Emerson NTQ123 specifications

Input voltage range85‑264 VAC
Input frequency47‑63 Hz
Inrush current38 A max
Efficiency65 % typical at full load
Power factor0.99 typical
Maximum power (convection cooling)70 W
Maximum power (forced air)120 W
Hold‑up time20 ms @ 120 W load
Operating temperature0 °C to 50 °C ambient
Storage temperature-40 °C to 85 °C
MTBF>1 million hours at full load

Source: EMERSON NETWORK POWER 70-120 Watts NTQ123 Series(1)

All Emerson NTQ123 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the input voltage range of the NTQ123 Series?

The unit accepts an input voltage range of 85 VAC to 264 VAC.

From: EMERSON NETWORK POWER 70-120 Watts NTQ123 Series(1)

What protection features are included?

It provides overload, short‑circuit, overvoltage, thermal overload, and power‑fail TTL signal protection.

From: EMERSON NETWORK POWER 70-120 Watts NTQ123 Series(1)

What is the input voltage range for the NTQ123 series?

The NTQ123 series accepts an input voltage range of 85 VAC to 264 VAC.

From: EMERSON NETWORK POWER 70-120 Watts NTQ123 Series

How is remote inhibit activated?

Remote inhibit requires an external TTL signal (5 V @ 10 mA) to activate.