Operation manual for automatic tuning of Yaskawa Sigma-7s, Sigma-M and Sigma-5 drives, covering setup steps, supported versions, error codes and travel limits.
This manual explains the automatic tuning operation for Yaskawa machine tool products using Sigma-7s, Sigma-M and Sigma-5 servo drives. It covers the menu path, supported firmware versions, the step-by-step tuning flow, tuning travel limits, and troubleshooting for tuning failure codes.
Automatic tuning measures the inertia ratio and adjusts servo parameters for the current mechanism type and load. The procedure is available in continuous jog, incremental jog and handwheel modes while the drive is ready, and the mode cannot be changed during tuning. This manual is written in Chinese.
| Sigma-7s supported versions (M3) | 10.116.36D, 10.116.39, 10.117.39 |
|---|---|
| Sigma-M supported versions (M3) | 10.116.36D, 10.116.39, 10.117.39 |
| Sigma-5 supported version (M2) | 10.116.16B |
| Sigma-7s supported versions (M2) | 10.116.24J, 10.116.31 |
| Sigma-M supported versions (M2) | 10.116.24K, 10.116.31 |
| Sigma 5 tuning travel upper limit | Motor 85 turns |
| Sigma 7 tuning travel upper limit | Motor 6 turns |
| Tuning travel lower limit | Linear axis: motor 4 turns; rotary axis: motor 2 turns |
| Tuning error code for tuning failure | 0x11 |
| Tuning error code for motion error | 0x21 |
| Tuning error code for inertia estimation failure | 0x31 |
Yes. Versions 10.116.24J, 10.116.31 and 10.117.31 support it.
Yes. It is supported from version 10.116.24K, 10.116.31 and 10.117.31 onward.
For Sigma 5 and Sigma M the upper limit is 85 motor turns; for Sigma 7 it is 6 motor turns. The lower limit is 4 motor turns for linear axes and 2 motor turns for rotary axes.