This manual provides installation instructions, safety precautions, and troubleshooting for the Yaskawa AC Drive 1000-Series Option PG-E3.
The document is an installation guide for the Yaskawa AC Drive 1000-Series Option PG-E3. It details receiving procedures, component identification, and step-by-step installation instructions including wiring requirements and safety warnings.
The option utilizes a rotary encoder (ERN1387) to detect motor speed and maintain constant motor speed by adjusting output frequency. The guide specifies applicable drive models, required tools, and terminal functions for proper setup.
The manual states that you must not allow the input frequency to exceed 20 kHz when operating the drive.
The option requires the drive to use Closed Loop Vector Control for PM to operate the motor.
You need a Phillips screwdriver with an M3 metric or #1, #2 U.S. standard size.