This manual provides installation procedures and minimum standards for the IronRidge Flush Mount system to ensure product reliability and warranty compliance.
The IronRidge Flush Mount Installation Manual outlines the proper installation procedures and minimum standards required for the reliability and warranty of the Flush Mount system. It covers the use of IronRidge parts or those recommended by the manufacturer, emphasizing that substituting parts may void the warranty. The guide includes specific instructions for attaching bases, placing rails, securing lugs, and mounting modules, along with details on expansion joints and electrical diagrams.
| System Fire Rating | Class A |
|---|---|
| Rail Torque | 250 in-lbs |
| Grounding Lug Torque | 80 in-lbs |
| Terminal Screw Torque | 20 in-lbs |
| Module Torque | 80 in-lbs |
| Standoff Torque | 140 in-lbs |
Grounding lugs are only needed on one rail per row of modules unless frameless modules are being used.
Yes, the rail and L-Feet can face either upslope or downslope on the roof.