IronRidge FRA-01 Flat Roof Attachment installation guide with parts list, tools, sealing requirements, torque value and structural certification details.
This two-page document covers the IronRidge Flat Roof Attachment, model FRA-01. Page one is a drawing with the parts list: the flat roof attachment base, the flat roof attachment membrane, a flat 3/8" x 1.25" OD stainless steel washer and a 3/8-16 x 1.125" hex stainless steel bolt. The attachment weighs 1.2 lbs and the document number is FRA-01-MAN REV 1.0.
Page two gives the installation steps: marking attachment locations, installing roof screws, attaching the rail mounting bracket with washers and 3/8" hardware torqued to 250 in-lbs (21 ft-lbs), and sealing the attachment and membrane per the roofing manufacturer's requirements. It also lists required tools, notes that the type, size and quantity of roof screws are specified by the Structural Engineer, and states the structural certification for the International Building Code, ASCE/SEI-7 and UL 2703.
| Weight | 1.2 lbs |
|---|---|
| Bolt | 3/8-16 x 1.125" hex, stainless steel |
| Washer | Flat 3/8" x 1.25" OD, stainless steel |
| Rail mounting bracket torque | 250 in-lbs (21 ft-lbs) |
| Maximum roof screw fastener size | #15 |
| Structural certification | International Building Code & ASCE/SEI-7 |
| UL standard | UL 2703 mechanical and bonding requirements |
Attach the rail mounting bracket with washers and 3/8" hardware torqued to 250 in-lbs (21 ft-lbs).
A tape measure, chalk, approved sealing materials, roof screws, and a driver with a 9/16" hex socket.
A roof manufacturer's approved sealant should be applied around the 3/8" bolt and in the bracket's slot before tightening the bolt.
The type, size and quantity of roof screws are specified by the Structural Engineer, and the fastener size must not exceed #15.