IronRidge All Tile Hook Flashing ATHF-MAN installation guide covering tools, the three-course sealing method, structural certification, and water seal ratings.
This installation guide covers the IronRidge All Tile Hook Flashing, identified by document number ATHF-MAN. It lists the tools and materials required, describes the three-course sealing method, and notes that installation follows TRI Guidelines.
The document also states structural certification for compliance with the International Building Code and ASCE/SEI-7, water seal ratings from UL 441 Section 27 and TAS 100(A)-95 testing by Intertek, and conformity to UL 2703 mechanical and bonding requirements.
| Structural Certification | Designed and certified for compliance with the International Building Code and ASCE/SEI-7 |
|---|---|
| Water Seal Test | Tested to UL 441 Section 27 Rain Test and TAS 100(A)-95 Wind Driven Rain Test by Intertek |
| Roof Slope Range | Applicable for concrete tile roofs with slopes between 2:12 and 12:12 |
| UL 2703 | Conforms to UL 2703 mechanical and bonding requirements |
| Sealant Requirement | Any roofing manufacturer approved sealant is allowed |
| Water Seal Testing | Tested and evaluated without sealant |
A caulking gun, roofing mastic, a trowel or applicator, and fabric reinforcement are required.
The guide describes applying sealant in a U shape, positioning the flashing over the base, and using the three-course sealing method with mastic and reinforcing fabric.
The ratings apply to concrete tile roofs having slopes between 2:12 and 12:12.
It is designed and certified for compliance with the International Building Code and ASCE/SEI-7.