Installation guide for the IronRidge XR100 and XR1000 ground mount solar racking system.
This manual covers installation of the IronRidge XR100 and XR1000 ground mount system, including base construction, substructure connection, rail placement, module securing, grounding, and optional accessories.
It also lists ratings, markings, required tools and components, torque values, module compatibility information, and electrical diagram details for installers.
| UL 2703 listing | UL 2703 LISTED |
|---|---|
| Maximum OCPD rating | 25A |
| Maximum module size | 24 ft² |
| Maximum frameless module size for Canadian LTR-AE | 19.5 ft² |
| CAMO allowable design load rating | 50 PSF downward, 50 PSF upward, 15 PSF lateral |
| LTR-AE Canadian load rating | 2400 Pa |
| System level allowable design load rating | meets minimum requirements of the standard (10 PSF downward, 5 PSF upward, 5 PSF lateral) |
Only one grounding lug is required per continuous subarray, regardless of subarray size, unless frameless modules are used.
The grounding lug is intended for use with one solid or stranded copper wire with conductor size 10-4 AWG.
No, CAMO is not compatible with Canadian Solar modules.
When installing CAMO, the module can overhang the rail no more than 1/4 inch.