IronRidge FlashVue FV-01 Flashing Installation Manual

Installation guide for the IronRidge FlashVue flashing, covering components, tools, mounting steps, structural certification, and water seal ratings.


IronRidge FlashVue FV-01 Flashing Installation Manual - cover page
Brand
IRONRIDGE
Category
Other products
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
3.7 MB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
18E2611CA4EE64DC3472B2E85A56EDFF

About this manual

IronRidge FlashVue (FV-01) is a roof flashing used in solar mounting installations. This document provides component details, required tools, and step-by-step installation instructions for mounting the flashing and attaching IronRidge XR Rails.

It also lists structural certification to the International Building Code and ASCE/SEI-7, water seal testing to UL 441 Section 27 and TAS 100(A)-95, and conformance to UL 2703 (2015) mechanical and bonding requirements.

What's inside

  • Installation
  • Tools Required
  • Structural Certification
  • Water Seal Ratings
  • UL 2703

Specifications

Weight0.6 lbs
Lag bolt5/16 x 4.25, 7/16 hex head
Rail attachment torque250 in-lbs (21 ft-lbs)
Pilot hole diameter1/4 in
Flashing top positionAt least 3/4 in above edge of 3rd course

Frequently asked questions

What tools are required to install FlashVue?

Tape measure, chalk, approved sealing materials, and a driver with a 1/4 in bit and 7/16 in hex socket.

To what standards is FlashVue structurally certified?

It is designed and certified for compliance with the International Building Code and ASCE/SEI-7.

What water seal tests were performed on FlashVue?

Water sealing was tested to UL 441 Section 27 “Rain Test” and TAS 100(A)-95 “Wind Driven Rain Test” by Intertek.

Does FlashVue conform to UL 2703?

Yes, it conforms to UL 2703 (2015) mechanical and bonding requirements.

Download PDF (3.7 MB)