VBAT-M46C is a pressure vessel with a maximum operating pressure of 1.5MPa and a capacity of 5L or 10L.
This is the SMC instruction manual (VBAT-M46C) for the VBAT05S1-U-X104 and VBAT10S1-U-X104 air tanks, which are listed as compliant with Chinese pressure vessel regulations. It gives the specifications of both tank types in a table, names each part and its function, and lists the accessories supplied with each tank.
The manual covers design and installation precautions, the procedure for assembling a booster valve (VBA1 or VBA2) onto the tank, tightening torques, outline dimensions, and maintenance points such as periodic inspection and daily draining of condensate. This manual is written in Chinese.
| Maximum operating pressure | 1.5 MPa |
|---|---|
| Material | SUS304 |
| Capacity | 5 L (VBAT05S1-U-X104), 10 L (VBAT10S1-U-X104) |
| Temperature range | 0 to 75 °C |
| Weight | 5.3 kg (VBAT05S1-U-X104), 8 kg (VBAT10S1-U-X104) |
| Port sizes | IN 3/8, OUT 3/8 (VBAT05S1); IN 3/8, OUT 1/2 (VBAT10S1); condensate 1/4 |
| Applicable booster valve | VBA1 (VBAT05S1); VBA1 or VBA2 (VBAT10S1) |
| Applicable standard | TSG R0003-2007 |
The tank must be used at a maximum operating pressure of 1.5 MPa or less, even when connected to a VBA1 booster valve.
VBAT05S1-U-X104 has a 5 L capacity and VBAT10S1-U-X104 has 10 L.
Condensate should be drained once a day, because retained condensate can affect downstream equipment and corrode the inside of the tank.
A hex wrench of 4 for VBA1 and 8 for VBA2 is required, and 6 for the condensate drain port.