SMC VBAT-M46C Air Tank VBAT05S1-U-X104 VBAT10S1-U-X104 Instruction Manual

VBAT-M46C is a pressure vessel with a maximum operating pressure of 1.5MPa and a capacity of 5L or 10L.


SMC VBAT-M46C Air Tank VBAT05S1-U-X104 VBAT10S1-U-X104 Instruction Manual - cover page
Brand
SMC
Category
Other
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
435 KB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
B1CFABC13F2B7801B1158484F6B89E9C

About this manual

This is the SMC instruction manual (VBAT-M46C) for the VBAT05S1-U-X104 and VBAT10S1-U-X104 air tanks, which are listed as compliant with Chinese pressure vessel regulations. It gives the specifications of both tank types in a table, names each part and its function, and lists the accessories supplied with each tank.

The manual covers design and installation precautions, the procedure for assembling a booster valve (VBA1 or VBA2) onto the tank, tightening torques, outline dimensions, and maintenance points such as periodic inspection and daily draining of condensate. This manual is written in Chinese.

What's inside

  • 各部分名称及功能
  • 规格
  • 同捆零部件
  • 使用注意事项(设计注意事项)
  • 安装注意事项
  • 配管
  • 排水阀
  • 气罐与增压阀的装配
  • 外形尺寸
  • 维修保养(保养、冷凝水排放)

Specifications

Maximum operating pressure1.5 MPa
MaterialSUS304
Capacity5 L (VBAT05S1-U-X104), 10 L (VBAT10S1-U-X104)
Temperature range0 to 75 °C
Weight5.3 kg (VBAT05S1-U-X104), 8 kg (VBAT10S1-U-X104)
Port sizesIN 3/8, OUT 3/8 (VBAT05S1); IN 3/8, OUT 1/2 (VBAT10S1); condensate 1/4
Applicable booster valveVBA1 (VBAT05S1); VBA1 or VBA2 (VBAT10S1)
Applicable standardTSG R0003-2007

Frequently asked questions

What is the maximum operating pressure of the air tank?

The tank must be used at a maximum operating pressure of 1.5 MPa or less, even when connected to a VBA1 booster valve.

What capacities are available?

VBAT05S1-U-X104 has a 5 L capacity and VBAT10S1-U-X104 has 10 L.

How often should condensate be drained?

Condensate should be drained once a day, because retained condensate can affect downstream equipment and corrode the inside of the tank.

Which hex wrenches are needed to assemble the booster valve?

A hex wrench of 4 for VBA1 and 8 for VBA2 is required, and 6 for the condensate drain port.

Download PDF (435 KB)