SMC ZSE10(F)/ISE10 Series Digital Pressure Switch Operation Manual
The SMC ZSE10(F)/ISE10 Series Digital Pressure Switch Operation Manual provides safety instructions and operating information for the digital pressure switch. The switch turns on when pressure exceeds a set value and turns off when pressure falls below the set value by the hysteresis amount or more.
It covers names and functions of the product, installation and mounting, piping and wiring, pressure setting in hysteresis and window comparator modes, function settings, maintenance, and troubleshooting including error indications.
| Piping port tightening torque (M5) | 1 Nm |
|---|---|
| Piping port tightening torque (R1/8, NPT1/8) | 7 to 9 Nm |
| Mounting screw size | M3 |
| Mounting screw tightening torque | 0.5 to 0.7 Nm |
| Default response time | 2.5 ms |
Use the increase button to raise the set value and the decrease button to lower it, then press SET to finish.
Turn off the power supply, stop the air supply, exhaust the residual pressure, and verify the air is released.
It lights ON when the switch output OUT1 is turned ON.
Yes, the product setting is retained as it was before the power cut or de-energizing.