Dixell XR60CX Temperature Controller Installation and User Manual

This manual introduces the operation of dIXEL XR60CX temperature controller, including installation, operation and parameter setting.


Dixell XR60CX Temperature Controller Installation and User Manual - cover page
Brand
dixell
Category
Temperature monitor
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
504 KB
Published
03 November, 2023
Updated
03 November, 2023
Model
XR60CX
MD5 checksum
6D2F90630EB66837CEBABF70C9F75D39

About this manual

This is the Chinese installation and use manual for the Dixell XR60CX, a micro electronic temperature controller measuring 32 x 74 x 60 mm, intended for medium and low temperature forced-air refrigeration systems. It has three outputs (compressor, evaporator fan and defrost) and accepts NTC or PTC probes for cabinet temperature and evaporator temperature, plus a configurable digital input or third probe.

The manual covers load output control, keypad and LED indicator operation, stored maximum and minimum temperatures, parameters, digital input, the TTL serial communication interface for monitoring systems, the optional X-REP remote display, mounting, electrical connections, the programming (hot) key, alarms, technical specifications, wiring diagrams and the parameter table with factory settings. This manual is written in Chinese.

What's inside

  • Precautions
  • Overview
  • Load Output Control
  • Keypad Operation
  • Maximum and Minimum Temperature Memory
  • Parameters
  • Digital Input
  • TTL Serial Communication Interface
  • X-REP Remote Display
  • Mounting

Specifications

Dimensions32 x 74 x 60 mm
Outputs3 outputs: compressor, evaporator fan, defrost (electric or hot gas)
Probe inputsThree NTC or PTC probe inputs (cabinet, evaporator, configurable)
Optional fourth probe inputConnected to terminals 2 and 4 of the 5-pin hot key connector (NG6-K connector, ordered separately)
CommunicationTTL serial interface; ModBUS-RTU network via optional XJ485-CX module
Defrost modestdF = EL electric defrost, tdF = in hot gas defrost

Frequently asked questions

What does the Dixell XR60CX control?

It controls a compressor, an evaporator fan and a defrost output (electric or hot gas) in forced-air refrigeration systems.

What are the dimensions of the XR60CX?

The controller measures 32 x 74 x 60 mm.

How do I start a manual defrost?

In normal (non-programming) mode press the defrost key; this is only possible if the evaporator probe value is below the dtE parameter setting.

Can the XR60CX be connected to a monitoring system?

Yes, the hot key port can be used with an XJ485-CX communication module to connect to a ModBUS-RTU compatible network such as the DIXELL XWEB monitoring systems.

Download PDF (504 KB)