About this manual

The WayCon WAY-AX is a display unit designed for industrial machines and systems, suitable for analog signals ranging from -10 to +10 V or 0/4 to 20 mA. It features a bright, high-contrast display with event-dependent color variations and supports intuitive parameterization via plain text and a touchscreen. The device offers various operating modes, including single-channel and dual-channel operations with combinations like sum, difference, multiplication, and division of inputs.

The manual covers safety instructions, electrical connections for power supply, auxiliary voltage, analog inputs, reference outputs, and control inputs. It details the configuration of optional features such as analog output, serial interface (RS232), control outputs, and relay outputs. Additionally, it explains the structure of the display and touch screen menus for parameterization and operation.

What's inside

  • Safety Instructions
  • Operation mode
  • Electrical Connections
  • Display and touch screen
  • Parameter Menu Structure
  • Analog Input
  • Control Inputs
  • Serial interface
  • Control-Output
  • Technical specifications

Specifications

Operating modesSINGLE, DUAL, IN 1 + IN 2, IN1 – IN 2, IN 1 x IN 2, IN 1 / IN 2
Analog inputsTwo universal 16 bit analog inputs
Reference output10 V
Housing dimensions3.78 x 1.89 inch
Protection ratingIP65
DC Power Supply18 to 30 V
Power consumptionapprox. 100 mA
Control output switching capability5 – 30 Volt / 200 mA per channel

Frequently asked questions

What is the permissible temperature range for installation?

The device is only allowed to be installed and operated within the permissible temperature range.

Can the device be used in explosion-proof areas?

No, the device is not suitable for operation in explosion-proof areas or areas excluded by the EN 61010-1 standard.

What is the maximum load for the reference-output?

The reference-output should be loaded with 10 mA maximum.

What is the maximum current for the auxiliary voltage output in the AC version?

The encoder voltage should be loaded with max. 150 mA up to 45 degrees Celsius.