This document provides information on the register settings and application instructions for the BDTIC angle sensor GMR angle sensor TLE5012B.
This document serves as the second part of the electrical specifications for the TLE5012B GMR angle sensor. It details the configuration of the Synchronous Serial Communication (SSC) interface, including specific register descriptions, bit definitions, and access permissions.
The guide covers the status register (STAT) and various interface mode registers (MOD_1 through MOD_4), explaining their functions and reset values. It also includes information on fuse values, CRC checks, and derivative-based resets to assist engineers in development and debugging. This manual is written in Chinese.
| Interface Type | Synchronous Serial Communication (SSC) |
|---|---|
| Document Version | 1.5 |
| Publisher | Infineon Technologies AG |
| Product Type | GMR Angle Sensor |
The main interface is the Synchronous Serial Communication (SSC) interface.
Fuse values are reset by laser fuses written during the sensor's factory calibration stage.
Yes, CRC checks can be disabled by setting the AS_FUSE register to 0.