Agilent LRIFLA Low Input RNA Amplification Application Note

This application note describes the application of the Low RNA Input Fluorescent Linear Amplification kit for the use of poly (A)+ RNA or total RNA samples. It shows that micrograms of cRNA targets can be generated within 6 hours, using as little as 10 ng of poly (A)+ RNA, or 50 ng of total RNA sample input. The resulting cRNA targets were of high quality and per- formed reproducibly and robustly on Agilent's oligonu- cleotide microarrays. Furthermore, the log ratios of array results from poly (A)+ RNA sample input correlated with that from total RNA input. The easy-to-use Low RNA Input Fluorescent Linear Amplification kit can be applied to a wide range of samples for gene expression analysis.


Agilent LRIFLA Low Input RNA Amplification Application Note - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
8
File format
PDF
File size
753 KB
Published
02 July, 2012
Updated
30 September, 2023
MD5 checksum
2280CB22DC6653E48425EAC6F21A7309

About this manual

Agilent Technologies developed the Low RNA Input Fluorescent Linear Amplification (LRIFLA) kit to address the challenge of using limited biological samples, such as rare primary cells or biopsy tissue, in DNA microarray analysis. The kit utilizes T7 RNA polymerase for a single round of linear amplification to produce sufficient quantities of fluorescently labeled cRNA or cDNA targets from as little as 10 ng of poly(A)* RNA or 50 ng of total RNA.

The document details experiments using HeLa and human spleen samples to demonstrate the kit's performance. Results show that micrograms of high-quality, labeled cRNA can be generated within six hours. The study confirms that the log ratios from arrays using amplified targets correlate well with those from standard total RNA inputs, validating the method for gene expression studies.

What's inside

  • Abstract
  • Introduction
  • Materials and Methods
  • Linear Amplification
  • Hybridization
  • Analysis
  • Results and Discussion

Frequently asked questions

How much poly (A)* RNA is required to generate cRNA targets?

The kit can produce high-quality cRNA targets using as little as 10 ng of poly (A)* RNA.

What is the maximum amount of total RNA that can be used for this amplification?

The procedure supports using up to 5000 ng of total RNA sample input.

How long does it take to generate micrograms of cRNA targets?

Micrograms of cRNA targets can be generated within 6 hours.

Download PDF (753 KB)

More Agilent Manuals


View all Agilent manuals →