Agilent 6890 Series Precise Time-Scaling of Gas Chromatographic Methods Using Method Translation and Retention Time Lock

This paper introduces a method for implementing precise time-scaled versions of a method on multiple instrument types using method translation combined with retention time locking (RTL). This method allows the original method to be reused with minimal effort, while optimizing the method for a given sample type or instrument setup.


Agilent 6890 Series Precise Time-Scaling of Gas Chromatographic Methods Using Method Translation and Retention Time Lock - cover page
Brand
Agilent
Category
Other Electronics
Document type
Application Note
Language
English
Pages
12
File format
PDF
File size
167 KB
Published
02 July, 2012
Updated
30 September, 2023
MD5 checksum
F0231A2850B4B467C73BFC2455498612

About this manual

This document explains how to implement precise time-scaled versions of gas chromatographic methods on multiple instrument types using method translation combined with retention time locking (RTL). It details how this approach allows an original method to be re-used with minimal effort while optimizing it for specific sample types or instrument configurations, thereby extending the utility of the original method.

The text outlines a specific workflow involving the Agilent RTL Pesticide Library method. It describes the steps required to scale a method, including determining a scale factor, calculating inlet pressure and oven temperature adjustments via method translation software, performing RTL calibration runs, and updating the retention time table to match the new scale factor.

What's inside

  • Abstract
  • Introduction
  • Method Translation
  • Retention Time Locking
  • Steps to Scale the Method
  • Experimental

Frequently asked questions

What is the primary purpose of the retention time locking (RTL) technique described in this note?

RTL is used to calculate the specific inlet pressure required to match retention times precisely after a method has been scaled.

How is the retention time table scaled when a new method is created?

The retention times in the table must be divided by the scale factor using a spreadsheet program like Microsoft Excel.

What specific hardware feature must the Agilent 6890 Series GC systems have to use this method?

All systems used for data collection in the examples were equipped with Electronic pneumatics control (EPC).