Agilent 6400 Series Dynamic MRM Application Note

The Dynamic MRM (DMRM) algorithm in the Agilent 6400 Series Triple Quadrupole LC/MS system automatically constructs DMRM timetables for multiple analytes throughout the LC/MS analysis based on the retention time window for each analyte. It allows the instrument to acquire MRM data only during a stated retention time window, thus reducing the number of concurrent ion transitions. In this study, 194 MRM transitions from a digest of complex protein standard was analyzed using DMRM and MRM modes in the Agilent 6410 Triple Quadrupole LC/MS system. Improved sensitivity, better peak symmetry, and up to ten-fold increase in the signal-to-noise (S/N) ratio are achieved using DMRM.


Agilent 6400 Series Dynamic MRM Application Note - cover page
Brand
Agilent
Category
Other Electronics
Document type
Application Note
Language
English
Pages
8
File format
PDF
File size
108 KB
Published
02 July, 2012
Updated
30 September, 2023
MD5 checksum
1B857362D99D4F61AA9AA907E5312A21

About this manual

The document describes the Dynamic MRM (DMRM) algorithm in the Agilent 6400 Series Triple Quadrupole LC/MS system, which automatically constructs timetables for multiple analytes based on retention time windows. This approach reduces the number of concurrent ion transitions, allowing the instrument to acquire MRM data only when compounds are expected to elute.

A study was conducted using the Agilent 6410 Triple Quadrupole LC/MS system to analyze 194 MRM transitions from a complex protein standard. The results showed that DMRM provides improved sensitivity, better peak symmetry, and up to a ten-fold increase in the signal-to-noise (S/N) ratio compared to standard MRM mode.

What's inside

  • Abstract
  • Introduction
  • Experimental Procedure
  • LC and MS conditions
  • Selection of MRM transitions
  • Results and Discussion
  • Conclusions

Specifications

System ModelAgilent 6400 Series Triple Quadrupole LC/MS system
Number of transitions analyzed194 MRM transitions
Dwell time (MRM mode)5 ms
Cycle time (MRM mode)1650 ms
Minimum dwell time (DMRM mode)53.4 ms

Frequently asked questions

What is the main advantage of Dynamic MRM (DMRM)?

DMRM reduces the number of concurrent ion transitions by acquiring MRM data only during stated retention time windows, which improves sensitivity and peak symmetry.

How much does DMRM improve the signal-to-noise ratio?

The study observed up to a ten-fold increase in the signal-to-noise (S/N) ratio when using DMRM compared to standard MRM.

Which Agilent system was used for the study?

The study utilized the Agilent 6410 Triple Quadrupole LC/MS system coupled to an HPLC-Chip/MS system.