About this manual

The DS 6 electronic pressure switch from BD Sensors is designed for use in mechanical manufacturing, hydraulic, measurement and control applications. It features a stainless‑steel pressure interface, ceramic A205 sensor and interchangeable sealing options for a wide range of media.

This manual covers safety warnings, unpacking, installation, electrical connection, initial start‑up, programming via CIS adapters, routine maintenance, calibration, warranty information and troubleshooting procedures. This manual is written in Chinese.

What's inside

  • Overview
  • Safety Instructions
  • Installation
  • Electrical Connection
  • Initial Start‑up
  • Operation & Programming
  • Maintenance
  • Calibration & Return to Factory
  • Warranty
  • Troubleshooting

Specifications

Maximum pressure range for oxygen applicationsup to 50 bar
Measurement limit for high‑pressure oxygen models215 bar / 95 °C

Frequently asked questions

What must be checked before the first start‑up?

The user must verify that the installation is correct and that there is no visible damage to the device.

What is the warranty period for the DS 6?

The product is covered by a free repair warranty for 24 months from the shipment date.

How can the DS 6 be programmed?

Programming is done with the CIS 680 or CIS 681 adapter and the P‑Set software via a serial or USB interface.