Multicomp ESD Monitored Workstation Kit Product Leaflet

This is an ESD Monitored Workstation Kit produced by Farnell. The kit includes ESD Mat, Caution Sign, Earth Facility Bracket, UK Earth Bonding Point, Power Supply Unit for EBP, Adjustable Wrist Strap Hypo Allergenic, Coiled Earth Lead and Straight Lead.


Multicomp ESD Monitored Workstation Kit Product Leaflet - cover page
Brand
MULTICOMP
Category
Other
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
75 KB
Published
09 April, 2012
Updated
30 September, 2023
MD5 checksum
D9210AF68759FA976A99187D68801D25

About this manual

The ESD Monitored Workstation Kit from Multicomp provides a complete anti‑static workstation solution. The kit includes a 600 × 900 mm ESD mat with a 10 mm stud in each corner, an ESD caution sign, earth bonding points with built‑in tester, a power supply unit, wrist‑strap set, earth leads, an earth‑facility bracket and an instruction leaflet.

The matting features a reflection‑breaking surface, high friction to prevent sliding, heat and oil resistance, and good scratch resistance. Detailed material properties such as static‑dissipative composition, hardness, surface resistance and dimensional stability are provided in the specifications section.

What's inside

  • Kit Includes
  • Matting Features
  • Matting Details
  • ESD Monitored Workstation Kit Contents
  • Disclaimer

Specifications

Mat materialStatic dissipative
Mat thickness2 mm
Hardness (ISO 7619)75+5 Shore A
Abrasion resistance (ISO 4649)<200 mm?
Indentation (EN433)<0.20 mm
Cigarette burning resistance (EN1399)No burn
Chemical resistance (EN423)Resistant to maintenance chemicals
Dimensional stability (EN424, 6 h/80 °C)<0.4 %
Surface resistance – top layer≈ 10⁸ Ω
Surface resistance – bottom layer≈ 10¹⁰ Ω
Straight earth lead resistivity1 MΩ ± 10 %
Straight earth lead diameter2.4 mm
Straight earth lead length12 ft
Earth Facility Bracket size40 × 45 × 12 mm

Frequently asked questions

What is the resistivity of the straight earth lead?

The straight earth lead has a resistivity of 1 MΩ ± 10 %.

Download PDF (75 KB)