MITSUBISHI ELECTRIC RD04HMS2 RD70HUF2 two-stage amplifier at f=330-400MHz.(Vdd=12.5V) Manual

AN-UHF-130 is an application note for Silicon RF Power Semiconductors. It introduces RD04HMS2 & RD70HUF2 two-stage amplifier


MITSUBISHI ELECTRIC RD04HMS2 RD70HUF2 two-stage amplifier at f=330-400MHz.(Vdd=12.5V) Manual - cover page
Brand
Mitsubishi
Category
Other Electronics
Document type
Application Note
Language
English
Pages
20
File format
PDF
File size
591 KB
Published
21 March, 2012
Updated
30 September, 2023
MD5 checksum
DDE5BE524C5AF89BA008AE4EB9BE181A

About this manual

The document provides an overview of the RDO4HMS2 and RD70HUF2 two‑stage RF power amplifiers, including their key features such as a 330‑400 MHz operating frequency, 12.5 V supply voltage, and output power of 79‑85 W. It also lists the quiescent and operating currents and the dimensions of the evaluation board (82.5 mm × 60.0 mm).

Detailed sections cover the equivalent circuitry, a complete component list with part numbers, standard land‑pattern dimensions, PCB layout drawings, and typical RF performance graphs (frequency response, output power versus input power, supply voltage, and gate voltage). The note is intended for engineers evaluating the amplifiers for RF applications.

What's inside

  • Equivalent Circuitry
  • Component List and Standard Deliverable
  • Standard Land Pattern Dimensions
  • PCB Layout
  • Typical RF Characteristics
  • Evaluation Board Details

Specifications

Operating frequency330‑400 MHz
Supply voltage (Vdd)12.5 V
Input power0.2 W
Output power79‑85 W
Quiescent current (RDO4HMS2)0.1 A
Quiescent current (RD70HUF2)1 A
Operating current9.5‑11 A
Evaluation board size82.5 mm × 60.0 mm

Frequently asked questions

What frequency range do the RDO4HMS2 and RD70HUF2 amplifiers cover?

They operate from 330 MHz to 400 MHz.

What supply voltage is required for the amplifiers?

A 12.5 V supply (Vdd) is required.

What is the output power capability of the amplifiers?

The output power ranges between 79 W and 85 W.

What are the quiescent currents of the two devices?

RDO4HMS2 draws 0.1 A and RD70HUF2 draws 1 A in quiescent mode.