Yaskawa FS100 Error 24: An error occurred in instruction prefetch queue operation.

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code24

An error occurred in instruction prefetch queue operation. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

Model
Yaskawa FS100
Display shows
An error occurred in instruction prefetch queue operation. (24)
Type
Alarm code
Source
Manual p. 229

What 24 means

An error occurred in instruction prefetch queue operation. p. 229

Common causes

  • Software operation error occurred p. 229

What to do

  1. (1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229
  2. (1)Reset the alarm., and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229

If 24 is still not resolved

  • (1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229
    “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

This page summarises what the manufacturer’s manual says about 24; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.