The system detected excessive segment motion in low/high range. The manual's first action is: “(1)Reduce the speed in the step where the alarm occurred. (2)Change the move instruction to joint interpolation (MOVJ). * Be careful to the peripheral interference since its movement changes.”
- Model
- Yaskawa FS100
- Display shows
- EXCESSIVE SEGMENT (LOW/HIGH) (4414)
- Type
- Alarm code
- Source
- Manual p. 233
What 4414 means
EXCESSIVE SEGMENT (LOW/HIGH) p. 233
Common causes
- Sub Code: Control group and axis p. 233
What to do
- (1)Reduce the speed in the step where the alarm occurred. (2)Change the move instruction to joint interpolation (MOVJ). * Be careful to the peripheral interference since its movement changes. p. 233
If 4414 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.
This page summarises what the manufacturer’s manual says about 4414; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.