Yaskawa FS100 Error 22: Undefined interrupt command was received.

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code22

An undefined interrupt command was received. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

Model
Yaskawa FS100
Display shows
Undefined interrupt command was received. (22)
Type
Alarm code
Source
Manual p. 229

What 22 means

Undefined interrupt command was received. p. 229

Common causes

  • Software operation error occurred p. 229

What to do

  1. (1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229
  2. (1)Reset the alarm., and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229

If 22 is still not resolved

  • If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 229
    “If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

This page summarises what the manufacturer’s manual says about 22; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.