Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Excessive error2 occurs when, upon turning the servo OFF, the actual position exceeds the excessive error width 2 value (parameter OD2). The manual lists no action for this code.
Excessive error1 happens when, upon turning the servo ON, the actual position exceeds the excessive error width 1 value (parameter OD1). The manual lists no action for this code.
Overload 2 occurs when a current command of 95% or more of the max. output current continues for 1 second or longer. The manual lists no action for this code.
Overload 1 indicates the motor was operated with the motor current in the overload range set in the overload detection level (parameter OLL) and overload time constant (parameter OLT). The manual lists no action for t…
Instantaneous stop indicates the control power was disconnected for 50ms or more. The manual lists no action for this code.
Motor overheat indicates the motor or detector thermal protector activated. The manual lists no action for this code.
Feedback error 2 indicates a deviation was detected in the motor end detector and machine end detector feedback amounts in a closed loop system. The manual lists no action for this code.
Feedback error 1 indicates a detector feedback signal pulse was omitted in the OHE-type/OHA-type detector used in a semiclosed loop system and ball screw end closed loop system. The manual lists no action for this code.
Power module error (overheat) indicates overheating of the IPM used in the inverter was detected. The manual lists no action for this code.
Overcurrent indicates an excessive current flowed in the motor. The manual lists no action for this code.
Protocol error 2 (information) indicates there is an error in the communication protocol with the NC. (Information error) The manual lists no action for this code.
Protocol error 1 (frame) indicates there is an error in the communication protocol with the NC. (Frame error) The manual lists no action for this code.
Initial parameter error indicates there is an error in the servo parameters transferred from the NC during servo drive initialization. The manual lists no action for this code.
Transferring error indicates the periodic data transfer from the NC was interrupted. The manual lists no action for this code.
Data error indicates the movement command data from the NC is abnormally large. The manual lists no action for this code.