Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The ratio between multi-turn resolution and modulo range is not an integer, causing position adjustment to reset. The manual's first action is: “Make the ratio between the multi-turn resolution and the modulo range an…
The "master control by PLC" signal was missing or incorrect, preventing proper master control operation. The manual's first action is: “Check the input for "master control by PLC".”
The motor's limit rotation parameter (p29027) is inappropriate and causing a test signal error. The manual's first action is: “Modify the value of parameter p29027.”
The upper torque limit parameter is set lower than the lower torque limit, which is invalid. The manual's first action is: “The upper torque limit (p29050) must be ≥ lower torque limit (p29051)”
Control parameters have exceeded dynamic limits and are not usable because hardware lacks required features. The manual's first action is: “It is not necessary to change the parameters as they have already been correc…
Motor overtemperature due to overload, high ambient temperature, or sensor disconnection. The manual's first action is: “Reduce the motor load.”
Exceeded the maximum allowable errors in controller sign-of-life during cyclic operation on PROFIdrive. The manual's first action is: “• Physically check the bus (cables, connectors, terminating resistor, shielding, e…
The global clock synchronization signal failed, violating time grid specifications in DP communication. The manual's first action is: “• Check the physical bus configuration (cable, connector, terminating resistor, sh…
Setpoints from the fieldbus interface (Modbus/USS) were not received due to communication interruption. The manual's first action is: “Restore the bus connection and set the controller to RUN.”
The drive's Safety Integrated (SI) function detected a defect and initiated an STO safety stop. The manual's first action is: “• Make sure that the high level duration of the input pulse is larger than 500 ms.”
For active PC master control, no sign-of-life signal was received within the monitoring time period. The manual's first action is: “Contact the Hotline.”
The module booting was interrupted several times, causing it to reset to factory settings. The manual's first action is: “Carry out a POWER ON (power off/on). After switching on, the module reboots from the valid para…
An internal software error has occurred on the Siemens SINAMICS V90, SIMOTICS S-1FL6 drive system. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”
A memory area was accessed that does not return a "READY" signal. The manual's first action is: “Carry out a POWER ON (power off/on).”
An internal software error has occurred. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”