Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Ground fault means a motor cable ground fault was detected. The manual lists no action for this code.
LSI error means an error occurred in LSI operation. The manual lists no action for this code.
No signal detection 2 means A, B or Z phase signals from machine-end detector have become "H" or "L". The manual lists no action for this code.
No signal detection 1 means A, B or Z phase signals from motor-end detector have become "H" or "L". The manual lists no action for this code.
Communication error (SUB) means communication was cut off with high-speed serial detector on machine end. The manual's first action is: “PR”
Thermal error (SUB) means thermal protector activated with high-speed serial detector on machine end. The manual's first action is: “PR”
Data error (SUB) means position per rotation data is corrupted when high-speed serial detector is connected to machine end. The manual's first action is: “PR”
LED error (SUB) means LED deterioration was detected with high-speed serial detector on machine end. The manual's first action is: “PR”
CPU error (SUB) means EEPROM data was corrupted when high-speed serial detector is connected to machine end. The manual's first action is: “PR”
Communication error (SUB) means initial communication failed with the OHA25K-ET machine end detector. The manual's first action is: “PR”
Initial communication error means absolute position or magnetic pole position data cannot be communicated with OHA-type detector or serial pulse encoder. The manual's first action is: “PR”
AD converter error means current detection AD converter failed to initialize correctly. The manual's first action is: “PR”
Magnetic pole position detect err 1 means one of the U, V or W phase signals from the OHE-type detector has become "H" or "L". The manual's first action is: “PR”
Software processing failed to complete within a specified time, possibly due to peripheral G/A errors. The manual's first action is: “PR”
A memory error has occurred due to an illegal checksum in the memory IC. The manual's first action is: “AR”