Emergency stop has been triggered, halting all operations until the emergency condition is cleared and restarted. The manual's first action is: “Restart after cancelling the emergency stop.”
Operation is blocked because an axis is already under control; restart after stopping current operation is required. The manual's first action is: “Restart after stopping the operation.”
An axis encountered an error during reference point return verification, requiring program review or correction. The manual's first action is: “Reconsider the program.”
The spindle rotation speed exceeded the allowable clamp speed during thread cutting, causing operational failure. The manual's first action is: “Decrease the spindle command rotation speed.”
Automatic operation paused because an axis has reached a stored stroke limit; manual cancellation is needed after resetting the system. The manual's first action is: “After resetting, cancel the stored stroke limit by…
Automatic operation paused because an axis has reached its physical stroke end; manual intervention is required after reset. The manual's first action is: “After resetting, cancel the stroke end by a manual operation.”
During reference point return, the near-point dog was passed over without stopping, likely due to insufficient length or misalignment. The manual's first action is: “Increase the length of the near-point dog.”
The machine’s stored stroke limits (limit 1 or 2) are active, indicating it has reached a programmed position boundary requiring manual adjustment. The manual's first action is: “The machine is at the stroke end, so m…
An axis has reached its physical stroke end and the limit switch is activated; manual movement is required to proceed. The manual's first action is: “The stroke end limit switch is activated (is at the stroke end), so…
Synchronous control was attempted without proper specifications configured, leading to an operational failure. The manual's first action is: “Check the specifications.”
The synchronization error between master and slave axes exceeded allowable limits during synchronous control operations. The manual's first action is: “In the correction mode, move one of the axes in the direction tha…
No absolute position reference point has been set, preventing accurate positioning and operation of the machine. The manual's first action is: “Set the absolute position reference point.”
The machine moved beyond the allowable amount while powered off, causing a positional tolerance violation during restart. The manual's first action is: “The tolerable movement amount is set in "270003 Move amnt in pwr…
The machine lost its absolute position data upon power-on, likely due to an error in checksum verification during startup. The manual's first action is: “Check the check sum.”
A spindle amplifier is incorrectly connected to a servo axis or vice versa; check the axis number settings for correct configuration. The manual's first action is: “PR”