The axis position exceeds the software limit switch plus setting. The manual's first action is: “• Correct the target position. • Change software limit switch plus (Cl: p2581).”
The axis position is below the software limit switch minus setting. The manual's first action is: “• Correct the target position. • Change software limit switch minus (Cl: p2580).”
The target position exceeds the software limit switch plus setting. The manual's first action is: “Correct the target position.”
The target position for relative movement is outside the allowed traversing range. The manual's first action is: “Correct the target position.”
The traversing block contains invalid information. The manual's first action is: “Check the traversing block and where relevant, take into consideration alarms that are present.”
The axis reached the zero mark and end of traversing range without detecting the reference cam input during search. The manual's first action is: “• Check the "reference cam" input. • Repeat the search for reference.”
The axis traveled the maximum permitted distance after leaving the reference cam without finding the zero mark. The manual's first action is: “• Check the encoder regarding zero mark. • Check the maximum permissible d…
The axis moved past the maximum permissible distance while searching for the reference cam without detecting it. The manual's first action is: “• Check the "reference cam" input. • Check the maximum permissible distan…
An error occurred during preprocessing of the position actual value from the encoder. The manual's first action is: “Check the encoder for the position actual value preprocessing.”
Following error exceeds tolerance limit, indicating significant deviation between setpoint and actual position. The manual's first action is: “Check the causes and resolve.”
Drive failed to reach positioning window within the set position monitoring time (p2545). The manual's first action is: “Check the causes and resolve.”
Drive exited the standstill monitoring window after the specified time expired. The manual's first action is: “Check the causes and resolve.”
Motor encoder moved beyond parameterized tolerance window during position tracking, causing loss of reference. The manual's first action is: “Reactivate the position tracking function (set p29243 = 1 -> 0 -> 1). Then …
Position tracking of load gear exceeded maximum absolute position actual value within 32-bit representation limits. The manual's first action is: “Reduce the multi-turn resolution (p29244).”
The reference point coordinate received for encoder adjustment lies outside the permissible range. The manual's first action is: “Set the reference point coordinate to a lower value than specified in the fault value. …