Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Failure during data copying because copying was halted, possibly due to micro SD card removal or drive not being stopped. The manual's first action is: “Re-plug in the micro SD card/SD card.”
Error bit set in the serial protocol when the encoder sends an error bit via the serial protocol. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”
Encoder 1: Absolute encoder signals Internal alarms because the absolute encoder fault word includes set alarm bits. The manual's first action is: “Check the encoder cable connection and make sure the cables are route…
Hardware current limiting in phase U when hardware current limit for phase U has responded, possibly due to incorrect parameterization or motor/power cable fault. The manual's first action is: “Check the motor data. A…
Load supply switched off because the DC link voltage is too low. The manual's first action is: “Switch on the load supply.”
PROFIdrive: Receive configuration data invalid due to a consistency error detected during configuration activation. The manual's first action is: “Check the required interface configuration, correct if necessary.”
PROFIdrive: No cyclic connection because there is no active cyclic connection to the control system. The manual's first action is: “Establish the cyclic connection and activate the control with cyclic operation.”
PROFIdrive: Receive configuration data invalid when the drive unit did not accept received configuration data. The manual's first action is: “Check the receive configuration data.”
Motor data identification active because the motor data identification routine is running and will complete on next power-on or restart. The manual's first action is: “The alarm automatically disappears after the moto…
Angular commutation offset determination activated as automatic encoder adjustment is being performed at next power-on. The manual's first action is: “The alarm automatically disappears after determination.”
Save required because the angular commutation offset was re-defined but not saved permanently. The manual's first action is: “This alarm automatically disappears after the data has been saved.”
Power unit overload I²t when the alarm threshold for power unit overload has been exceeded. The manual's first action is: “Reduce the continuous load.”
EPOS: Software limit switch plus reached when the axis has reached the software limit switch plus position while an active traversing block was interrupted. The manual's first action is: “Correct the target position. …
EPOS: Software limit switch minus reached when the axis has reached the software limit switch minus position while an active traversing block was interrupted. The manual's first action is: “Correct the target position.”
EPOS: Target position > software limit switch plus when the target position is greater than the software limit switch plus during traversal. The manual's first action is: “Correct the target position.”