Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Variable names have been commanded improperly in the program. The manual's first action is: “Reconsider the variable names in the program and correct them.”
A WHILE or GOTO statement is present during tape operation, which prevents execution and switches to memory mode. The manual lists no action for this code.
The DOs and ENDS are not paired off properly in the program. The manual's first action is: “Reconsider the program and correct it so that the DOs and ENDS are paired off properly.”
The number of DO - END statements within a WHILE loop exceeds the maximum allowed limit of 27. The manual's first action is: “Reconsider the program and correct it so that the number of the DO - END statements does no…
A SETVN statement has an invalid variable name, which must be 7 characters or fewer in length. The manual's first action is: “Reconsider the program. • The number of characters in the variable name of the SETVN statem…
The WHILE [
There is an error in the IF [
A variable's data has overflowed beyond acceptable limits in the program. The manual's first action is: “Reconsider the variable data in the program.”
An integer value during processing exceeded -2^31, causing an overflow error. The manual's first action is: “Review the program's operation expression, and correct so that the operated integer value does not exceed -2…
A division operation was attempted with zero as the denominator, which is mathematically undefined. The manual's first action is: “Reconsider the program and correct it so that the denominator for division in the form…
An arithmetic formula in the program is incorrect or invalid for calculation. The manual's first action is: “Reconsider the program to correct the arithmetic formula.”
The number of opening and closing parentheses [ ] in a block does not match, indicating improper pairing. The manual's first action is: “Reconsider the program and correct it so that the "[" and "]" parentheses are pa…
Too many parentheses [.] have been used in a single block of code, exceeding the five-pair limit. The manual's first action is: “Reconsider the program and correct it so that the number of "[" or "]" does not exceed f…
An alarm command has been issued in #3000, which is not allowed by the system. The manual's first action is: “Refer to OPERATOR MESSAGE on DIAGN screen. Refer to instruction manual issued by machine manufacturer.”
A G67 command was issued without first issuing a G66 command to enable it. The manual's first action is: “Reconsider the program. The G67 command is the call cancel command and so the G66 command must be designated fi…