Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
RESERVED is not used on this product. The manual's first action is: “Not used.”
SHORT CIRC indicates a fault current caused by a short-circuit in motor cables or supply disturbances. The manual's first action is: “Check for and correct: A short-circuit in the motor cable(s) or motor. Supply distu…
DEV OVERTEMP means the drive heatsink is overheated due to fan failure, obstructions, dust, ambient heat, or excessive load. The manual's first action is: “R1...R4 & R7/R8: 115 °C (239 °F) R5/R6: 125 °C (257 °F). Chec…
DC OVERVOLT indicates intermediate circuit DC voltage is too high from input power issues, deceleration settings, or overvoltage conditions. The manual's first action is: “Check for and correct: Static or transient ov…
OVERCURRENT means output current is excessive due to motor load, acceleration time settings, or faulty components. The manual's first action is: “Check for and correct: Excessive motor load. Insufficient acceleration …
All 128 error codes of the ABB ACH550 AC drive with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
The centrifuge has a problem requiring maintenance by service personnel. The manual's first action is: “Contact Hitachi Koki service representative.”
The centrifuge has a problem requiring maintenance by service personnel. The manual's first action is: “Contact Hitachi Koki service representative.”
Rotor speed is set higher than the maximum allowable speed. The manual's first action is: “Set the speed within the permitted limits.”
START key is pressed with the door opened, or the door handle is released while the rotor is rotating. The manual's first action is: “Close the door and start operation. If the door handle is released, lock it again i…
TEMP display shows a temperature over 50°C, or a temperature lower or higher than the set temperature more than 20°C. The manual's first action is: “Lower the room temperature if it is over 35°C. Clean the radiator if…
Rotor is not properly secured to the drive spindle or the rotor in use is not entered to the centrifuge, or the sensor on the back of the door becomes wet. The manual's first action is: “Make sure the rotor is secured…
A power failure occurred while the rotor was spinning and the speed decreased by 300 rpm from the set speed. The manual's first action is: “Check the run time if the rotor has stopped and restart operation if necessary.”
All 7 error codes of the Hitachi CR22G/CR21G high-speed refrigerated centrifuge with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
The machine is overheated, which can have several causes. The manual's first action is: “Switch the machine off and switch it back on again after 30 minutes. Try this 2 or 3 times.”