Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
RESERVED is an unused code without defined meaning or cause. The manual lists no action for this code.
SERF CORRUPT error indicates an internal drive error requiring contact with ABB support. The manual's first action is: “Contact your local ABB sales representative and report the error number.”
USER LOAD CURVE error happens when a user-defined load curve condition exceeds its allowed time duration. The manual lists no action for this code.
CB OVERTEMP indicates the drive control board has overheated due to ambient temperature, fan failure, or obstructions. The manual's first action is: “Check for and correct: • Excessive ambient temperatures • Fan failu…
INCOMP SWTYPE error occurs when the loaded software is incompatible with the drive. The manual's first action is: “• Internal Fault. • The loaded software is not compatible with the drive. • Call support representative.”
OUTPUT WIRING error detects possible power wiring errors between drive input and output. The manual's first action is: “When the drive is not running it monitors for an improper connection between the drive input powe…
MOTOR PHASE error signals a motor phase loss in the motor circuit. The manual's first action is: “Check for and correct: • Motor fault. • Motor cable fault. • Thermal relay fault (if used). • Internal fault.”
EFB 3 is an unused fault code as of this manual’s publication. The manual lists no action for this code.
EFB 2 is an unused fault code as of this manual’s publication. The manual lists no action for this code.
EFB 1 is a reserved fault code for EFB protocol applications and not currently used. The manual's first action is: “These codes are not used as of the publication of this manual.”
FORCE TRIP indicates a fault trip was triggered by the fieldbus system. The manual's first action is: “See the fieldbus User's Manual.”
EFB CONFIG FILE error happens when the embedded fieldbus configuration file cannot be read correctly. The manual lists no action for this code.
SERIAL 1 ERR means fieldbus communication has timed out due to setup, settings, or line issues. The manual's first action is: “Check for and correct: • Fault setup (3018 COMM FAULT FUNC and 3019 COMM FAULT TIME). • Co…
CONFIG FILE error indicates an internal configuration file has a problem. The manual's first action is: “Contact your local ABB sales representative.”
DRIVE ID error occurs when the internal configuration block for drive identification is invalid. The manual's first action is: “Contact your local ABB sales representative.”