Agilent MSD Security ChemStation is a data management software that can be used to control data acquisition, perform library searches and quantitative analysis, and generate selected reports via methods or sequences. The software addresses all aspects of data security, integrity, and traceability mandated by FDA’s 21 CFR Part 11. The solution represents a significant productivity advance for pharmaceutical laboratories. Access to the application is protected by a mandatory logon with a user identification code and password. Paper trails are replaced by audit-proof and reliable electronic records. The software manages versions electronically and provides a user-independant audit trail along with electronic signing capabilities. Electronic records generated by the application are always linked to all related raw, meta, and result data. The MSD Security ChemStation software is designed to run on personal computers with Microsoft® Windows® operating environments. The MSD Security ChemStation software is supplied on CD-ROM and contains extensive online help with both task and reference information about system operation. The example methods and data files supplied with the software can be used to practice and learn the MSD Security ChemStation software. The MSD Security ChemStation software can be configured to support a single online instrument, with a maximum of one MSD and one GC detector. The following Agilent instruments are supported: • The new 5975 series MSDs 5973A, 5973N, and 5973 inert MSDs • 6850 GC p
The Agilent MSD Security ChemStation software controls data acquisition, performs library searches, and generates reports for GC/MS systems. It addresses data security and integrity requirements mandated by FDA's 21 CFR Part 11, providing electronic records and audit trails. The software is designed to run on personal computers with Microsoft Windows operating environments.
| Supported Operating Systems | Windows 2000 Professional, Service Pack 4; Windows XP Professional, Service Pack 2 |
|---|---|
| Minimum RAM | 128 MB |
| Recommended RAM | 512 MB or greater |
| Hard Disk Storage | 80 GB |
| Processor (Minimum) | Pentium III, 600 MHz or faster |
| Processor (Recommended) | Pentium IV, 2.8 GHz or faster |
| Supported GC Detectors | TCD, FID, ECD, u-ECD, FPD, NPD |
| Supported Printers | HP LaserJet 2200d, 2300dn, 4050, 4100, 4020 |
It supports 5973A, 5973N, 5973 inert, and 5975 series MSDs, along with 6850, 6890A, 6890 Plus, and 6890N GCs.
No, the software is not supported on Windows 2000 Server, Windows 2003 Server, or Windows NT Workstation.
The software supports standard LAN communications and GPIB communications depending on the instrument configuration.